Removed Stoping states
This commit is contained in:
@@ -151,9 +151,8 @@ record(bi , "$(P)$(R)TMPump2-Acceleration") {
|
||||
####################################
|
||||
record(bi , "$(P)$(R)TTSystem-tzero" ) {
|
||||
field(DESC,"Trigger control 60s before shot")
|
||||
# record(bi , "$(P)$(R)TimingTriggerSignal" ) {
|
||||
field(INP, "$(P)$(R)PCF8574:57:REGISTER:READ.B7")
|
||||
field(SCAN, "1 second" )
|
||||
# field(INP, "$(P)$(R)PCF8574:57:REGISTER:READ.B7")
|
||||
field(VAL,"1")
|
||||
field(ZNAM, "OFF" )
|
||||
field(ONAM, "ON" )
|
||||
}
|
||||
@@ -231,9 +230,10 @@ record( bo, "$(P)$(R)RPump1-Motor" ) {
|
||||
# field(DESC," Liga a alimentação da bomba rotatória 1 ")
|
||||
#record( bo, "$(P)$(R)RotatoryPump" ) {
|
||||
field(OUT, "$(P)$(R)PCF8574:60:REGISTER.B0 PP" )
|
||||
field(ZNAM, "On" )
|
||||
field(ONAM, "Off" )
|
||||
field(ZNAM, "Off" )
|
||||
field(ONAM, "On" )
|
||||
field(VAL,"1")
|
||||
field(ZSV,"MINOR")
|
||||
}
|
||||
|
||||
#############################
|
||||
@@ -242,9 +242,9 @@ record( bo, "$(P)$(R)RPump1-Motor" ) {
|
||||
record( bo, "$(P)$(R)RPump1-Valve" ) {
|
||||
field(DESC,"Abre a valvula da bomba rotatoria 1 ")
|
||||
# record( bo, "$(P)$(R)RotatoryValve" ) {
|
||||
field( OUT, "$(P)$(R)PCF8574:60:REGISTER.B1 PP" )
|
||||
field( ZNAM, "Open" )
|
||||
field( ONAM, "Closed" )
|
||||
field(OUT, "$(P)$(R)PCF8574:60:REGISTER.B1 PP" )
|
||||
field(ZNAM, "Closed" )
|
||||
field(ONAM, "Open" )
|
||||
field(VAL,"1")
|
||||
}
|
||||
|
||||
@@ -253,11 +253,11 @@ record( bo, "$(P)$(R)RPump1-Valve" ) {
|
||||
#############################
|
||||
record( bo, "$(P)$(R)RPump2-Motor" ) {
|
||||
field(DESC,"Power On Rotatory Pump 2")
|
||||
#record( bo, "$(P)$(R)RotatoryPump2" ) {
|
||||
field( OUT, "$(P)$(R)PCF8574:60:REGISTER.B2 PP" )
|
||||
field( ZNAM, "On" )
|
||||
field( ONAM, "Off" )
|
||||
field(OUT, "$(P)$(R)PCF8574:60:REGISTER.B2 PP" )
|
||||
field(ZNAM, "Off" )
|
||||
field(ONAM, "On" )
|
||||
field(VAL,"1")
|
||||
field(ZSV,"MINOR")
|
||||
}
|
||||
|
||||
#############################
|
||||
@@ -265,10 +265,9 @@ record( bo, "$(P)$(R)RPump2-Motor" ) {
|
||||
#############################
|
||||
record( bo, "$(P)$(R)RPump2-Valve" ) {
|
||||
field(DESC," Abre a valvula da bomba rotatoria 2 ")
|
||||
#record( bo, "$(P)$(R)RotatoryValve2" ) {
|
||||
field(OUT, "$(P)$(R)PCF8574:60:REGISTER.B3 PP" )
|
||||
field(ZNAM, "Open" )
|
||||
field(ONAM, "Closed" )
|
||||
field(ZNAM, "Closed" )
|
||||
field(ONAM, "Open" )
|
||||
field(VAL,"1")
|
||||
}
|
||||
|
||||
|
||||
@@ -64,12 +64,12 @@ record(calc, "$(P)$(R)STARTCALCSTATE") {
|
||||
field(INPA,"$(P)$(R)STARTINGSTATE.VAL PP NMS")
|
||||
}
|
||||
|
||||
record(calc, "$(P)$(R)STOPCALCSTATE") {
|
||||
field(DESC, "Stop Calculated State")
|
||||
field(CALC,"2^A")
|
||||
field(SCAN,"1 second")
|
||||
field(INPA,"$(P)$(R)STOPPINGSTATE.VAL PP NMS")
|
||||
}
|
||||
#record(calc, "$(P)$(R)STOPCALCSTATE") {
|
||||
# field(DESC, "Stop Calculated State")
|
||||
# field(CALC,"2^A")
|
||||
# field(SCAN,"1 second")
|
||||
# field(INPA,"$(P)$(R)STOPPINGSTATE.VAL PP NMS")
|
||||
#}
|
||||
|
||||
record(calc, "$(P)$(R)CLEANCALCSTATE") {
|
||||
field(DESC, "Clean Automatic Calculated State")
|
||||
@@ -195,22 +195,22 @@ record(mbbi, "$(P)$(R)STARTINGSTATE") {
|
||||
field(VAL, "0")
|
||||
}
|
||||
|
||||
record(mbbi, "$(P)$(R)STOPPINGSTATE") {
|
||||
field(DESC, "Stopping State Sequence")
|
||||
field(ZRVL, "0")
|
||||
field(ONVL, "1")
|
||||
field(TWVL, "2")
|
||||
field(THVL, "3")
|
||||
field(FRVL, "4")
|
||||
field(FVVL, "5")
|
||||
field(ZRST, "NonStopped")
|
||||
field(ONST, "Stopping1")
|
||||
field(TWST, "Stopping2")
|
||||
field(THST, "Stopping3")
|
||||
field(FRST, "Stopping4")
|
||||
field(FVST, "Stopping5")
|
||||
field(VAL, "0")
|
||||
}
|
||||
#record(mbbi, "$(P)$(R)STOPPINGSTATE") {
|
||||
# field(DESC, "Stopping State Sequence")
|
||||
# field(ZRVL, "0")
|
||||
# field(ONVL, "1")
|
||||
# field(TWVL, "2")
|
||||
# field(THVL, "3")
|
||||
# field(FRVL, "4")
|
||||
# field(FVVL, "5")
|
||||
# field(ZRST, "NonStopped")
|
||||
# field(ONST, "Stopping1")
|
||||
# field(TWST, "Stopping2")
|
||||
# field(THST, "Stopping3")
|
||||
# field(FRST, "Stopping4")
|
||||
# field(FVST, "Stopping5")
|
||||
# field(VAL, "0")
|
||||
#}
|
||||
|
||||
record(mbbi, "$(P)$(R)CLEANINGSTATE") {
|
||||
field(DESC, "Cleaning State Sequence")
|
||||
|
||||
Reference in New Issue
Block a user