Change PV names and state machine

This commit is contained in:
Bernardo Carvalho
2019-11-27 18:07:24 +00:00
parent 1ef0124eed
commit dabf6bdf9d
9 changed files with 1503 additions and 2317 deletions

View File

@@ -0,0 +1,421 @@
###############
###############
# REGISTER 56 #
###############
###############
#####################################
### 24V commands - Optocoupler Out###
#####################################
record(bo, "$(P)$(R)TMPump1-ControllerOn" ) {
# field(DESC,"Sinal p/ TMP 1, Liga a alimentação do controlador, vai a HIGH e depois a LOW")
# field( ZNAM, "Off" )record(bo, "$(P)$(R)TMPControllerOn" ) {
field(ZNAM, "Off" )
field(ONAM, "Pulse" )
field(HIGH, "2.5")
field(FLNK, "$(P)$(R)TMPump1-ControllerOnInv" )
# field( FLNK, "$(P)$(R)TMPControllerOnInv" )
}
record(calcout, "$(P)$(R)TMPump1-ControllerOnInv" ) {
#record(calcout, "$(P)$(R)TMPControllerOnInv" ) {
field( INPA, "$(P)$(R)TMPControllerOn NPP MS" )
field( OUT, "$(P)$(R)PCF8574:56:REGISTER.B0 PP MS" )
field( OOPT, "On Change" )
field( CALC, "A?0:1" )
}
record(bo, "$(P)$(R)TMPump1-ControllerOff" ) {
# field(DESC," Sinal p/ TMP 1, desliga a alimentação do controlador, LOW->HIGH-> LOW")
# record(bo, "$(P)$(R)TMPControllerOff" ) {
field(ZNAM, "Off" )
field(ONAM, "Pulse" )
field(HIGH, "2.5")
#field( FLNK, "$(P)$(R)TMPControllerOffInv" )
field(FLNK, "$(P)$(R)TMPump1-ControllerOffInv" )
}
record(calcout, "$(P)$(R)TMPump1-ControllerOffInv") {
field( INPA, "$(P)$(R)TMPump1-ControllerOff NPP MS" )
field( OUT, "$(P)$(R)PCF8574:56:REGISTER.B1 PP MS")
field( OOPT, "On Change" )
field( CALC, "A?0:1" )
}
record(bo, "$(P)$(R)TMPump1-MotorOn" ) {
field( ZNAM, "Off")
field( ONAM, "Pulse")
field( HIGH, "2.5")
field( FLNK, "$(P)$(R)TMPump1-MotorOnInv")
}
record(calcout, "$(P)$(R)TMPump1-MotorOnInv" ) {
field( INPA, "$(P)$(R)TMPump1-MotorOn NPP MS")
field( OUT, "$(P)$(R)PCF8574:56:REGISTER.B2 PP MS")
field( OOPT, "On Change")
field( CALC, "A?0:1" )
}
record(bo, "$(P)$(R)TMPump1-MotorOff") {
field( ZNAM, "Off")
field( ONAM, "Pulse")
field( HIGH, "2.5")
field( FLNK, "$(P)$(R)TMPump1-MotorOffInv")
}
record(calcout, "$(P)$(R)TMPump1-MotorOffInv") {
field( INPA, "$(P)$(R)TMPump1-MotorOff NPP MS")
field( OUT, "$(P)$(R)PCF8574:56:REGISTER.B3 PP MS")
field( OOPT, "On Change")
field( CALC, "A?0:1")
}
#############################
### TMP1 Controller inputs###
#############################
record(fanout, "$(P)$(R)PCF8574:56:REGISTER:READ:FNOUT"){
field(LNK1, "$(P)$(R)TMPump1-Power")
field(LNK2, "$(P)$(R)TMPump1-Emergency")
field(LNK3, "$(P)$(R)TMPump1-Acceleration")
field(LNK4, "$(P)$(R)TMPump1-NormalOperation")
# field(LNK2, "$(P)$(R)Turbo_Emergency")
}
record(bi , "$(P)$(R)TMPump1-Power" ) {
field(DESC," TMP1 Alimentada 220V ")
#record(bi , "$(P)$(R)Turbo_PW_Ind" ) {
field( INP, "$(P)$(R)PCF8574:56:REGISTER:READ.B4 NPP NMS")
# field( SCAN, "1 second")
field( ZNAM, "ON" )
field( ONAM, "OFF" )
# field(FLNK, "$(P)$(R)Turbo_Emergency")
}
record(bi , "$(P)$(R)TMPump1-Emergency") {
field(DESC," TMP1 Falha ")
#record(bi , "$(P)$(R)Turbo_Emergency") {
field( INP, "$(P)$(R)PCF8574:56:REGISTER:READ.B5 NPP NMS")
field( ZNAM, "ON" )
field( ONAM, "OFF" )
field(ZSV,"MAJOR")
# field(FLNK, "$(P)$(R)Turbo_Acceleration")
}
record(bi , "$(P)$(R)TMPump1-Acceleration") {
field(DESC," TMP1 Motor em aceleração ")
#record(bi , "$(P)$(R)Turbo_Acceleration") {
field( INP, "$(P)$(R)PCF8574:56:REGISTER:READ.B6 NPP NMS")
field( ZNAM, "ON" )
field( ONAM, "OFF" )
# field(FLNK, "$(P)$(R)Turbo_NormalOperation")
}
record(bi , "$(P)$(R)TMPump1-NormalOperation" ) {
field(DESC," TMP1 Operação Normal ")
#record(bi , "$(P)$(R)Turbo_NormalOperation" ) {
field( INP, "$(P)$(R)PCF8574:56:REGISTER:READ.B7 NPP NMS")
field( ZNAM, "ON" )
field( ONAM, "OFF" )
field(OSV,"MINOR")
}
###############
###############
# REGISTER 57 #
###############
###############
##############################
### TMP2 Controller Inputs ###
##############################
record(fanout, "$(P)$(R)PCF8574:57:REGISTER:READ:FNOUT"){
field(LNK1, "$(P)$(R)TMPump2-Emergency")
field(LNK2, "$(P)$(R)TMPump2-Acceleration")
}
record(bi , "$(P)$(R)TMPump2-Emergency") {
field(DESC," TMP2 Falha ")
field( INP, "$(P)$(R)PCF8574:57:REGISTER:READ.B0 NPP NMS")
field( ZNAM, "ON" )
field( ONAM, "OFF" )
# field(FLNK, "$(P)$(R)Turbo2_Acceleration")
}
record(bi , "$(P)$(R)TMPump2-Acceleration") {
field(DESC," TMP2 START until Normal ")
field( INP, "$(P)$(R)PCF8574:57:REGISTER:READ.B1 NPP NMS")
field( ZNAM, "ON" )
field( ONAM, "OFF" )
}
###############################
### TMP2 Controller Outputs ###
###############################
record(bo, "$(P)$(R)TMP2MotorOnOff" ) {
field( OUT, "$(P)$(R)PCF8574:57:REGISTER.B2 PP MS")
field( ZNAM, "ON")
field( ONAM, "OFF")
}
##############################
# BUZZER ON/OFF #
##############################
record(bo, "$(P)$(R)Buzzer" ) {
field( ZNAM, "Off" )
field( ONAM, "Pulse" )
field( HIGH, "2.5")
field( FLNK, "$(P)$(R)BuzzerInv" )
}
record(calcout, "$(P)$(R)BuzzerInv" ) {
field( INPA, "$(P)$(R)Buzzer NPP MS" )
field( OUT, "$(P)$(R)PCF8574:57:REGISTER.B3 PP MS" )
field( OOPT, "On Change" )
field( CALC, "A?0:1" )
}
##############################
# EMERGENCY MODE #
##############################
record( bo, "$(P)$(R)EmergencyButton" ) {
field(DESC," Botao fisico que executa a soft Emergency ")
field( OUT, "$(P)$(R)PCF8574:57:REGISTER.B4 PP" )
field( ZNAM, "On" )
field( ONAM, "Off")
}
############
# NOT USED #
############
#$(P)$(R)PCF8574:57:REGISTER:READ.B5
#$(P)$(R)PCF8574:57:REGISTER:READ.B6
####################################
# TIMING TRIGGER ON/OFF #
####################################
record(bi , "$(P)$(R)TimingTriggerSignal" ) {
field( INP, "$(P)$(R)PCF8574:57:REGISTER:READ.B7")
field( SCAN, "1 second" )
field( ZNAM, "OFF" )
field( ONAM, "ON" )
}
###############
###############
# REGISTER 60 #
###############
###############
#############################
# ROTARY1 PUMP #
#############################
record( bo, "$(P)$(R)RPump1-Motor" ) {
# field(DESC," Liga a alimentação da bomba rotatória 1 ")
#record( bo, "$(P)$(R)RotatoryPump" ) {
field( OUT, "$(P)$(R)PCF8574:60:REGISTER.B0 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
}
#############################
# ROTARY1 VALVE #
#############################
record( bo, "$(P)$(R)RPump1-Valve" ) {
field(DESC," Abre a valvula da bomba rotatoria 1 ")
# record( bo, "$(P)$(R)RotatoryValve" ) {
field( OUT, "$(P)$(R)PCF8574:60:REGISTER.B1 PP" )
field( ZNAM, "Open" )
field( ONAM, "Closed" )
}
#############################
# ROTARY2 PUMP #
#############################
record( bo, "$(P)$(R)RPump2-Motor" ) {
field(DESC," Liga a alimentacao da bomba rotatoria 2 ")
#record( bo, "$(P)$(R)RotatoryPump2" ) {
field( OUT, "$(P)$(R)PCF8574:60:REGISTER.B2 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
}
#############################
# ROTARY2 VALVE #
#############################
record( bo, "$(P)$(R)RPump2-Valve" ) {
field(DESC," Abre a valvula da bomba rotatoria 2 ")
#record( bo, "$(P)$(R)RotatoryValve2" ) {
field( OUT, "$(P)$(R)PCF8574:60:REGISTER.B3 PP" )
field( ZNAM, "Open" )
field( ONAM, "Closed" )
}
################################
# FILAMENT ON/OFF #
################################
record(bo, "$(P)$(R)VVessel-Filament" ) {
field(DESC," Filamento dentro do TOK para pre ionizar a câmara")
# record(bo, "$(P)$(R)FilamentOnOff" ) {
field( OUT, "$(P)$(R)PCF8574:60:REGISTER.B4 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
}
##############################
# LIGHTS ON/OFF #
##############################
record(bo, "$(P)$(R)Lab-WarningLight" ) {
field(DESC," Luzes de sinalização, 220V ")
# record(bo, "$(P)$(R)LightsOnOff" ) {
field( OUT, "$(P)$(R)PCF8574:60:REGISTER.B5 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
}
############
# NOT USED #
############
#$(P)$(R)PCF8574:60:REGISTER:READ.B6
##############################
# TOR CLEAN CONTACTOR ON/OFF #
##############################
record(bo, "$(P)$(R)Clean-TorContactor" ) {
# field(DESC," Contactor 220V do transformador para a fonte de campo toroidal das descargas de limpeza (500 A) ")
# record(bo, "$(P)$(R)ToroidalCleanContactorOnOff" ) {
field( OUT, "$(P)$(R)PCF8574:60:REGISTER.B7 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
}
###############
###############
# REGISTER 61 #
###############
###############
############################
# TOR CLEAN BREAKER ON/OFF #
############################
record(bo, "$(P)$(R)Clean-TorPneuBreaker" ) {
## field(DESC," Interruptor de ar comprimido do transformador para a fonte de campo toroidal das descargas de limpeza (500 A)")
#record(bo, "$(P)$(R)ToroidalCleanBreakerOnOff" ) {
field( OUT, "$(P)$(R)PCF8574:61:REGISTER.B0 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
}
record(bo, "$(P)$(R)Shot-TorPSDisable" ) {
# field(DESC," É desligado na emergência e em qualquer estado que não seja Process ou Wait Shot.")
# record(bo, "$(P)$(R)ToroidalShotEnableOnOff" ) {
field( OUT, "$(P)$(R)PCF8574:61:REGISTER.B1 PP" )
field( ZNAM, "Off" )
field( ONAM, "On" )
}
record(bo, "$(P)$(R)Shot-TorPSTrigger" ) {
field(DESC," Trigger da FRAEP")
# record(bo, "$(P)$(R)ToroidalShotTriggerOnOff" ) {
field( ZNAM, "Off" )
field( ONAM, "Pulse" )
field( HIGH, "2.5")
field( FLNK, "$(P)$(R)Shot-TorPSTriggerInv" )
# field( FLNK, "$(P)$(R)ToroidalShotTriggerOnOffInv" )
}
record(calcout, "$(P)$(R)Shot-TorPSTriggerInv" ) {
# field(DESC," $(R)")
#record(calcout, "$(P)$(R)ToroidalShotTriggerOnOffInv" ) {
field( INPA, "$(P)$(R)ToroidalShotTriggerOnOff NPP MS" )
field( OUT, "$(P)$(R)PCF8574:61:REGISTER.B2 PP MS" )
field( OOPT, "On Change" )
field( CALC, "A?0:1" )
}
############################################################
#######################################
# CAP BANK CHARGE ON/OFF #
#######################################
record(bo, "$(P)$(R)CapBank-Charge" ) {
## field(DESC," Contactor 220V do circuito de carga do banco de condensadores p/ SHOT (ELCO) ")
#record(bo, "$(P)$(R)CapBankChargeOnOff" ) {
field( OUT, "$(P)$(R)PCF8574:61:REGISTER.B3 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
}
########################################
# PRIMARY CLEAN CONTACTOR ON/OFF #
########################################
record(bo, "$(P)$(R)Clean-PrimContactor" ) {
# field(DESC," Contactor 220V do para o primário das descargas de limpeza ")
# record(bo, "$(P)$(R)PrimaryCleanContactorOnOff" ) {
field( OUT, "$(P)$(R)PCF8574:61:REGISTER.B4 PP MS" )
field( ZNAM, "On" )
field( ONAM, "Off" )
}
####################################
### PRIMARY CLEAN BREAKER ON/OFF ###
####################################
record(bo, "$(P)$(R)Clean-PrimPneuBreaker"){
#record(bo, "$(P)$(R)PrimaryCleanBreakerOnOff"){
field( DESC, "Primary Cleaning OnOff")
field( OUT, "$(P)$(R)PCF8574:61:REGISTER.B5 PP" )
field( ZNAM, "On")
field( ONAM, "Off")
}
##################################
# GIS VALVES ON/OFF #
##################################
record(bo, "$(P)$(R)GasIS-Valves" ) {
# field(DESC," 2 válvulas pneumáticas de corte do sistema de injecção de H/D/Ne/He no TOK, 24V out = deixa passar")
# record(bo, "$(P)$(R)GISValvesOnOff" ) {
field( OUT, "$(P)$(R)PCF8574:61:REGISTER.B6 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
}
##########################################
# CAP BANK DISCHARGE ON/OFF #
##########################################
record(bo, "$(P)$(R)CapBank-Discharge" ) {
field(DESC," Liga o circuito de descarga do ELCO ")
# record(bo, "$(P)$(R)CapBankDischargeOnOff" ) {
field( OUT, "$(P)$(R)PCF8574:61:REGISTER.B7 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
}
#########################
###Pressure Conditions###
#########################
record(ao,"$(P)$(R)Pressure_PrimaryCondition"){
field(VAL,"5.0e-3")
field(PREC,"3")
field(EGU,"mBar")
}
record(ao,"$(P)$(R)Pressure_Primary2Condition"){
field(VAL,"5.0e-3")
field(PREC,"3")
field(EGU,"mBar")
}
record(ai,"$(P)$(R)Bypass_Condition"){
field(VAL,"0")
}
record(ai,"$(P)$(R)TMPump2-Speed"){
# field(DESC," ADC Pump speed 0-10V ")
#record(ai,"$(P)$(R)Turbo2_Speed"){
field(PREC,"3")
field(EGU,"RPM")
field(VAL,"0")
}
#######################
###TMP1 Manual Valve###
#######################
record(bo, "$(P)$(R)TMPump1-ManualValve"){
# field(DESC," $(R)")
#record(bo, "$(P)$(R)TMPManualValve"){
info(autosaveFields, "VAL")
field( DESC, "State of manual valve")
field( ZNAM, "Closed")
field( ONAM, "Open")
}