@@ -18,18 +18,18 @@
# ### Read/Write pcf8574 address 0x38=56 register ### #
###################################################
record( mbboDirect, "$(P)$(R)PCF8574:56:REGISTER") {
field( DTYP, "stream")
field( OUT, "@pcf8574.proto wReg(56) I2C")
field( SHFT, "0")
field( NOBT, "8")
field(DTYP, "stream")
field(OUT, "@pcf8574.proto wReg(56) I2C")
field(SHFT, "0")
field(NOBT, "8")
# Has @init on protocol
# field(VAL, 255)
# field(PINI,"YES")
}
record( mbbiDirect, "$(P)$(R)PCF8574:56:REGISTER:READ" ) {
field( DTYP, "stream")
field( INP, "@pcf8574.proto rReg(56) I2C")
field(DTYP, "stream")
field(INP, "@pcf8574.proto rReg(56) I2C")
field(NOBT, "8")
field(SCAN, "1 second")
field(FLNK, "$(P)$(R)PCF8574:56:REGISTER:READ:FNOUT")
@@ -40,20 +40,21 @@ record( mbbiDirect, "$(P)$(R)PCF8574:56:REGISTER:READ" ) {
# ### Read/Write pcf8574 address 0x39=57 register ### #
###################################################
record( mbboDirect, "$(P)$(R)PCF8574:57:REGISTER") {
field( DTYP, "stream")
field( OUT, "@pcf8574.proto wReg(57) I2C")
field( SHFT, "0")
field( NOBT, "8")
field(VAL, 255)
field(PINI,"YES")
field(DTYP, "stream")
field(OUT, "@pcf8574.proto wReg(57) I2C")
field(SHFT, "0")
field(NOBT, "8")
# field(VAL, 255)
# field(PINI,"YES")
}
record( mbbiDirect, "$(P)$(R)PCF8574:57:REGISTER:READ" ) {
field( DTYP, "stream")
field( INP, "@pcf8574.proto rReg(57) I2C")
field(DTYP, "stream")
field(INP, "@pcf8574.proto rReg(57) I2C")
field(NOBT, "8")
field(SCAN, "1 second")
field(PINI,"YES")
field(FLNK, "$(P)$(R)PCF8574:57:REGISTER:READ:FNOUT")
# field(PINI,"YES")
}
#####################################################
@@ -64,8 +65,8 @@ record( mbboDirect, "$(P)$(R)PCF8574:60:REGISTER") {
field( OUT, "@pcf8574.proto wReg(60) I2C")
field( SHFT, "0")
field( NOBT, "8")
field(VAL, 255)
field(PINI,"YES")
#field(VAL, 255)
#field(PINI,"YES")
}
record( mbbiDirect, "$(P)$(R)PCF8574:60:REGISTER:READ" ) {
@@ -73,7 +74,8 @@ record( mbbiDirect, "$(P)$(R)PCF8574:60:REGISTER:READ" ) {
field( INP, "@pcf8574.proto rReg(60) I2C")
field(NOBT, "8")
field(SCAN, "1 second")
field(PINI,"YES")
# field(FLNK, "$(P)$(R)PCF8574:60:REGISTER:READ:FNOUT")
#field(PINI,"YES")
}
#####################################################
@@ -84,8 +86,8 @@ record( mbboDirect, "$(P)$(R)PCF8574:61:REGISTER") {
field( OUT, "@pcf8574.proto wReg(61) I2C")
field( SHFT, "0")
field( NOBT, "8")
field(VAL, 255)
field(PINI,"YES")
#field(VAL, 255)
#field(PINI,"YES")
}
record( mbbiDirect, "$(P)$(R)PCF8574:61:REGISTER:READ" ) {
@@ -93,5 +95,6 @@ record( mbbiDirect, "$(P)$(R)PCF8574:61:REGISTER:READ" ) {
field( INP, "@pcf8574.proto rReg(61) I2C")
field(NOBT, "8")
field(SCAN, "1 second")
field(PINI,"YES")
#field(PINI,"YES")
# field(FLNK, "$(P)$(R)PCF8574:61:REGISTER:READ:FNOUT")
}

View File

@@ -9,7 +9,7 @@
# ### ### #
# ### macros: ID I2C address of ADC ### #
# ### Description: ### #
# ### This is an example DB file using ### #
# ### This DB file is using ### #
# ### stream(asynI2C) to read/write ### #
# ### an PCF8591 ADDA chip ### #
#######################################################
@@ -29,7 +29,6 @@ record( mbboDirect, "$(P)$(R)PCF8591:72:CTRLREGISTER") {
record( longin, "$(P)$(R)PCF8591:72:ADC_CH1" ) {
field(DTYP, "stream")
field(INP, "@pcf8591.proto rConvAdc0(72) I2C")
# field( FLNK, "$(P)$(R)PCF8591:72:CHANNEL1" )
}
record( calc, "$(P)$(R)PCF8591:72:BYTE2_CH1" ) {
field(INPA, "$(P)$(R)PCF8591:72:ADC_CH1 PP NMS")
@@ -37,21 +36,25 @@ record( calc, "$(P)$(R)PCF8591:72:BYTE2_CH1" ) {
field(CALC, " (A & 255 )" )
}
record( ai, "$(P)$(R)TMP2Speed" ) {
field( DTYP, "Raw Soft Channel" )
field( INP, "$(P)$(R)PCF8591:72:BYTE2_CH1 PP NMS")
field( SCAN, "1 second")
field( ASLO, "16" )
field( AOFF, "0" )
field( EGU, "RPM" )
field( PREC, "3" )
field( HOPR, "5000" )
field( LOPR, "0" )
record( ai, "$(P)$(R)TMPump2-Speed" ) {
field(DESC, "TMPump2-Speed")
field(DTYP, "Raw Soft Channel" )
field(INP, "$(P)$(R)PCF8591:72:BYTE2_CH1 PP NMS")
field(SCAN, "1 second")
field(ASLO, "16" )
field(AOFF, "0" )
field(EGU, "RPM" )
field(PREC, "3" )
field(HOPR, "5000" )
field(LOPR, "0" )
field(LOW, "200.0")
# # field(LOLO,"0.0")
field(LSV, "MINOR")
# # field(LLSV,"MAJOR")
}
record( longin, "$(P)$(R)PCF8591:72:ADC_CH2" ) {
field(DTYP, "stream")
field(INP, "@pcf8591.proto rConvAdc1(72) I2C")
#field( FLNK, "
}
record( calc, "$(P)$(R)PCF8591:72:BYTE2_CH2" ) {
field(INPA, "$(P)$(R)PCF8591:72:ADC_CH2 PP NMS")
@@ -59,9 +62,10 @@ record( calc, "$(P)$(R)PCF8591:72:BYTE2_CH2" ) {
field(CALC, " (A & 255)" )
}
record( ai, "$(P)$(R)TMP2Current" ) {
record( ai, "$(P)$(R)TMPump2-Current" ) {
field(DESC, "TMPump2-Current")
field(DTYP, "Raw Soft Channel" )
field(INP, "$(P)$(R)PCF8591:72:BYTE2_CH2 PP NMS")
field(INP, "$(P)$(R)PCF8591:72:BYTE2_CH2 PP NMS")
field(SCAN, "1 second")
field(ASLO, "0.1" )
field(AOFF, "0" )
@@ -69,4 +73,8 @@ record( ai, "$(P)$(R)TMP2Current" ) {
field(PREC, "3" )
field(HOPR, "50" )
field(LOPR, "0" )
field(LOW, "2.0")
# # field(LOLO,"0.0")
field(LSV, "MINOR")
# # field(LLSV,"MAJOR")
}

View File

@@ -40,6 +40,14 @@ record (calc, "$(P)$(R)RPump1-Pressure")
field(CALC, "(A*0.001)*10.0**(B-20)")
field(PREC, "3")
field(EGU, "mBar")
field(HIHI,"1.0e-1")
field(HIGH,"5.0e-3")
# field(LOW, "20.0")
# field(LOLO,"0.0")
field(HHSV,"MAJOR")
field(HSV, "MINOR")
# field(LSV, "MINOR")
# field(LLSV,"MAJOR")
}
record (longin, "$(P)$(R)P003:M")
@@ -88,6 +96,14 @@ record (calc, "$(P)$(R)RPump2-Pressure")
field(CALC, "(A*0.001)* 10.0**(B-20)")
field(PREC, "3")
field(EGU, "mBar")
field(HIHI,"1.0e-1")
field(HIGH,"5.0e-3")
# field(LOW, "20.0")
# field(LOLO,"0.0")
field(HHSV,"MAJOR")
field(HSV, "MINOR")
# field(LSV, "MINOR")
# field(LLSV,"MAJOR")
}
record(stringout,"$(P)$(R)RS485Debug") {

View File

@@ -42,35 +42,35 @@ record(calc, "$(P)$(R)OPCALCSTATE") {
field(INPA,"$(P)$(R)OPSTATE.VAL PP NMS")
}
record(calc, "$(P)$(R)OPCALCSTARTSTATE") {
record(calc, "$(P)$(R)STARTCALCSTATE") {
field(DESC, "Start Calculated State")
field(CALC,"2^A")
field(SCAN,"1 second")
field(INPA,"$(P)$(R)STARTINGSTATE.VAL PP NMS")
}
record(calc, "$(P)$(R)OPCALCSTOPSTATE") {
record(calc, "$(P)$(R)STOPCALCSTATE") {
field(DESC, "Stop Calculated State")
field(CALC,"2^A")
field(SCAN,"1 second")
field(INPA,"$(P)$(R)STOPPINGSTATE.VAL PP NMS")
}
record(calc, "$(P)$(R)OPCALCACLEANSTATE") {
record(calc, "$(P)$(R)CLEANCALCSTATE") {
field(DESC, "Clean Automatic Calculated State")
field(CALC,"(2^(A+1))-1")
field(SCAN,"1 second")
field(INPA,"$(P)$(R)CLEANINGSTATE.VAL PP NMS")
}
record(calc, "$(P)$(R)OPCALCMCLEANSTATE") {
field(DESC, "Clean Manual Calculated State")
field(CALC,"2^A")
field(SCAN,"1 second")
field(INPA,"$(P)$(R)CLEANINGSTATE.VAL PP NMS")
}
#record(calc, "$(P)$(R)OPCALCMCLEANSTATE") {
# field(DESC, "Clean Manual Calculated State")
# field(CALC,"2^A")
# field(SCAN,"1 second")
# field(INPA,"$(P)$(R)CLEANINGSTATE.VAL PP NMS")
#}
record(calc, "$(P)$(R)OPCALCWSHOTSTATE") {
record(calc, "$(P)$(R)WSHOTCALCSTATE") {
field(DESC, "WaitShot Calculated State")
field(CALC,"2^A")
field(SCAN,"1 second")
@@ -90,49 +90,15 @@ record(bo, "$(P)$(R)OPREQ") {
field(ONAM, "START")
}
record(bo, "$(P)$(R)CLEANINGMASTATE") {
record(bo, "$(P)$(R)CLEANINGMANMODE") {
field(DESC, "Cleaning Manual/Auto")
field(VAL, "1")
field(ZNAM, "M")
field(ONAM, "A")
}
record(ai, "$(P)$(R)CLEANINGINOUTSTATE") {
field(DESC, "Cleaning Automatic In/Out")
field(VAL, "1")
}
record(ai, "$(P)$(R)CLEANINGINOUTSTATE0") {
field(DESC, "Cleaning Automatic In/Out")
field(VAL, "-2")
}
record(ai, "$(P)$(R)CLEANINGINOUTSTATE1") {
field(DESC, "Cleaning Automatic In/Out")
field(VAL, "-2")
}
record(ai, "$(P)$(R)CLEANINGINOUTSTATE2") {
field(DESC, "Cleaning Automatic In/Out")
field(VAL, "-2")
}
record(ai, "$(P)$(R)CLEANINGINOUTSTATE3") {
field(DESC, "Cleaning Automatic In/Out")
field(VAL, "-2")
}
record(ai, "$(P)$(R)CLEANINGINOUTSTATE4") {
field(DESC, "Cleaning Automatic In/Out")
field(VAL, "-2")
}
record(ai, "$(P)$(R)CLEANINGINOUTSTATE5") {
field(DESC, "Cleaning Automatic In/Out")
field(VAL, "-2")
}
record(bo, "$(P)$(R)FSTriggerState") {
record(bo, "$(P)$(R)FSTriggerStart") {
field(DESC, "FireSignal Trigger Start")
field(VAL, "0")
field(ZNAM, "STOP")
@@ -246,7 +212,7 @@ record(mbbi, "$(P)$(R)CLEANINGSTATE") {
}
record(mbbi, "$(P)$(R)WSHOTINGSTATE") {
field(DESC, "Shoting State Sequence")
field(DESC, "Shooting State Sequence")
field(ZRVL, "0")
field(ONVL, "1")
field(TWVL, "2")
@@ -259,18 +225,18 @@ record(mbbi, "$(P)$(R)WSHOTINGSTATE") {
field(NIVL, "9")
field(TEVL, "10")
field(ELVL, "11")
field(ZRST, "NonShoting")
field(ONST, "Shoting1")
field(TWST, "Shoting2")
field(THST, "Shoting3")
field(FRST, "Shoting4")
field(FVST, "Shoting5")
field(SXST, "Shoting6")
field(SVST, "Shoting7")
field(EIST, "Shoting8")
field(NIST, "Shoting9")
field(TEST, "Shoting10")
field(ELST, "Shoting11")
field(ZRST, "NonShooting")
field(ONST, "Shooting1")
field(TWST, "Shooting2")
field(THST, "Shooting3")
field(FRST, "Shooting4")
field(FVST, "Shooting5")
field(SXST, "Shooting6")
field(SVST, "Shooting7")
field(EIST, "Shooting8")
field(NIST, "Shooting9")
field(TEST, "Shooting10")
field(ELST, "Shooting11")
field(VAL, "0")
}

View File

@@ -7,57 +7,64 @@
#####################################
### 24V commands - Optocoupler Out###
#####################################
record(bo, "$(P)$(R)TMPControllerOn" ) {
field( ZNAM, "Off" )
field( ONAM, "Pulse" )
field( HIGH, "2.5")
field( FLNK, "$(P)$(R)TMPControllerOnInv" )
}
record(bo, "$(P)$(R)TMPump1-ControllerOn" ) {
# field(DESC,"Sinal p/ TMP 1, Liga a alimentação do controlador, vai a HIGH e depois a LOW")
# field( ZNAM, "Off" )record(bo, "$(P)$(R)TMPControllerOn" ) {
field(ZNAM, "Off" )
field(ONAM, "Pulse" )
field(HIGH, "2.5")
field(FLNK, "$(P)$(R)TMPump1-ControllerOnInv" )
record(calcout, "$(P)$(R)TMPControllerOnInv" ) {
# field( FLNK, "$(P)$(R)TMPControllerOnInv" )
}
record(calcout, "$(P)$(R)TMPump1-ControllerOnInv" ) {
#record(calcout, "$(P)$(R)TMPControllerOnInv" ) {
field( INPA, "$(P)$(R)TMPControllerOn NPP MS" )
field( OUT, "$(P)$(R)PCF8574:56:REGISTER.B0 PP MS" )
field( OOPT, "On Change" )
field( CALC, "A?0:1" )
}
record(bo, "$(P)$(R)TMPControllerOff" ) {
field( ZNAM, "Off" )
field( ONAM, "Pulse" )
field( HIGH, "2.5")
field( FLNK, "$(P)$(R)TMPControllerOffInv" )
record(bo, "$(P)$(R)TMPump1-ControllerOff" ) {
# field(DESC," Sinal p/ TMP 1, desliga a alimentação do controlador, LOW->HIGH-> LOW")
# record(bo, "$(P)$(R)TMPControllerOff" ) {
field(ZNAM, "Off" )
field(ONAM, "Pulse" )
field(HIGH, "2.5")
#field( FLNK, "$(P)$(R)TMPControllerOffInv" )
field(FLNK, "$(P)$(R)TMPump1-ControllerOffInv" )
}
record(calcout, "$(P)$(R)TMPControllerOffInv") {
field( INPA, "$(P)$(R)TMPControllerOff NPP MS" )
record(calcout, "$(P)$(R)TMPump1-ControllerOffInv") {
field( INPA, "$(P)$(R)TMPump1-ControllerOff NPP MS" )
field( OUT, "$(P)$(R)PCF8574:56:REGISTER.B1 PP MS")
field( OOPT, "On Change" )
field( CALC, "A?0:1" )
}
record(bo, "$(P)$(R)TMPMotorOn" ) {
record(bo, "$(P)$(R)TMPump1-MotorOn" ) {
field( ZNAM, "Off")
field( ONAM, "Pulse")
field( HIGH, "2.5")
field( FLNK, "$(P)$(R)TMPMotorOnInv")
field( FLNK, "$(P)$(R)TMPump1-MotorOnInv")
}
record(calcout, "$(P)$(R)TMPMotorOnInv" ) {
field( INPA, "$(P)$(R)TMPMotorOn NPP MS")
record(calcout, "$(P)$(R)TMPump1-MotorOnInv" ) {
field( INPA, "$(P)$(R)TMPump1-MotorOn NPP MS")
field( OUT, "$(P)$(R)PCF8574:56:REGISTER.B2 PP MS")
field( OOPT, "On Change")
field( CALC, "A?0:1" )
}
record(bo, "$(P)$(R)TMPMotorOff") {
record(bo, "$(P)$(R)TMPump1-MotorOff") {
field( ZNAM, "Off")
field( ONAM, "Pulse")
field( HIGH, "2.5")
field( FLNK, "$(P)$(R)TMPMotorOffInv")
field( FLNK, "$(P)$(R)TMPump1-MotorOffInv")
}
record(calcout, "$(P)$(R)TMPMotorOffInv") {
field( INPA, "$(P)$(R)TMPMotorOff NPP MS")
record(calcout, "$(P)$(R)TMPump1-MotorOffInv") {
field( INPA, "$(P)$(R)TMPump1-MotorOff NPP MS")
field( OUT, "$(P)$(R)PCF8574:56:REGISTER.B3 PP MS")
field( OOPT, "On Change")
field( CALC, "A?0:1")
@@ -67,35 +74,46 @@ record(calcout, "$(P)$(R)TMPMotorOffInv") {
### TMP1 Controller inputs###
#############################
record(fanout, "$(P)$(R)PCF8574:56:REGISTER:READ:FNOUT"){
field(LNK1, "$(P)$(R)Turbo_PW_Ind")
field(LNK2, "$(P)$(R)Turbo_Emergency")
field(LNK1, "$(P)$(R)TMPump1-Power")
field(LNK2, "$(P)$(R)TMPump1-Emergency")
field(LNK3, "$(P)$(R)TMPump1-Acceleration")
field(LNK4, "$(P)$(R)TMPump1-NormalOperation")
# field(LNK2, "$(P)$(R)Turbo_Emergency")
}
record(bi , "$(P)$(R)Turbo_PW_Ind" ) {
record(bi , "$(P)$(R)TMPump1-Power" ) {
field(DESC," TMP1 Alimentada 220V ")
#record(bi , "$(P)$(R)Turbo_PW_Ind" ) {
field( INP, "$(P)$(R)PCF8574:56:REGISTER:READ.B4 NPP NMS")
# field( SCAN, "1 second")
field( ZNAM, "ON" )
field( ONAM, "OFF" )
# field(FLNK, "$(P)$(R)Turbo_Emergency")
}
record(bi , "$(P)$(R)Turbo_Emergency") {
record(bi , "$(P)$(R)TMPump1-Emergency") {
field(DESC," TMP1 Falha ")
#record(bi , "$(P)$(R)Turbo_Emergency") {
field( INP, "$(P)$(R)PCF8574:56:REGISTER:READ.B5 NPP NMS")
field( ZNAM, "ON" )
field( ONAM, "OFF" )
field(FLNK, "$(P)$(R)Turbo_Acceleration")
field(ZSV,"MAJOR")
# field(FLNK, "$(P)$(R)Turbo_Acceleration")
}
record(bi , "$(P)$(R)Turbo_Acceleration") {
record(bi , "$(P)$(R)TMPump1-Acceleration") {
field(DESC," TMP1 Motor em aceleração ")
#record(bi , "$(P)$(R)Turbo_Acceleration") {
field( INP, "$(P)$(R)PCF8574:56:REGISTER:READ.B6 NPP NMS")
field( ZNAM, "ON" )
field( ONAM, "OFF" )
field(FLNK, "$(P)$(R)Turbo_NormalOperation")
# field(FLNK, "$(P)$(R)Turbo_NormalOperation")
}
record(bi , "$(P)$(R)Turbo_NormalOperation" ) {
record(bi , "$(P)$(R)TMPump1-NormalOperation" ) {
field(DESC," TMP1 Operação Normal ")
#record(bi , "$(P)$(R)Turbo_NormalOperation" ) {
field( INP, "$(P)$(R)PCF8574:56:REGISTER:READ.B7 NPP NMS")
field( ZNAM, "ON" )
field( ONAM, "OFF" )
field(OSV,"MINOR")
}
###############
@@ -107,15 +125,21 @@ record(bi , "$(P)$(R)Turbo_NormalOperation" ) {
##############################
### TMP2 Controller Inputs ###
##############################
record(bi , "$(P)$(R)Turbo2_Emergency") {
record(fanout, "$(P)$(R)PCF8574:57:REGISTER:READ:FNOUT"){
field(LNK1, "$(P)$(R)TMPump2-Emergency")
field(LNK2, "$(P)$(R)TMPump2-Acceleration")
}
record(bi , "$(P)$(R)TMPump2-Emergency") {
field(DESC," TMP2 Falha ")
field( INP, "$(P)$(R)PCF8574:57:REGISTER:READ.B0 NPP NMS")
field( ZNAM, "ON" )
field( ONAM, "OFF" )
field(FLNK, "$(P)$(R)Turbo2_Acceleration")
# field(FLNK, "$(P)$(R)Turbo2_Acceleration")
}
record(bi , "$(P)$(R)Turbo2_Acceleration") {
field( INP, "$(P)$(R)PCF8574:57:REGISTER:READ.B1 NPP NMS")
record(bi , "$(P)$(R)TMPump2-Acceleration") {
field(DESC," TMP2 START until Normal ")
field( INP, "$(P)$(R)PCF8574:57:REGISTER:READ.B1 NPP NMS")
field( ZNAM, "ON" )
field( ONAM, "OFF" )
}
@@ -132,14 +156,14 @@ record(bo, "$(P)$(R)TMP2MotorOnOff" ) {
##############################
# BUZZER ON/OFF #
##############################
record(bo, "$(P)$(R)BuzzerOnOff" ) {
record(bo, "$(P)$(R)Buzzer" ) {
field( ZNAM, "Off" )
field( ONAM, "Pulse" )
field( HIGH, "2.5")
field( FLNK, "$(P)$(R)BuzzerOnOffInv" )
field( FLNK, "$(P)$(R)BuzzerInv" )
}
record(calcout, "$(P)$(R)BuzzerOnOffInv" ) {
field( INPA, "$(P)$(R)BuzzerOnOff NPP MS" )
record(calcout, "$(P)$(R)BuzzerInv" ) {
field( INPA, "$(P)$(R)Buzzer NPP MS" )
field( OUT, "$(P)$(R)PCF8574:57:REGISTER.B3 PP MS" )
field( OOPT, "On Change" )
field( CALC, "A?0:1" )
@@ -148,7 +172,8 @@ record(calcout, "$(P)$(R)BuzzerOnOffInv" ) {
##############################
# EMERGENCY MODE #
##############################
record( bo, "$(P)$(R)EmergencyOnOff" ) {
record( bo, "$(P)$(R)EmergencyButton" ) {
field(DESC," Botao fisico que executa a soft Emergency ")
field( OUT, "$(P)$(R)PCF8574:57:REGISTER.B4 PP" )
field( ZNAM, "On" )
field( ONAM, "Off")
@@ -179,7 +204,9 @@ record(bi , "$(P)$(R)TimingTriggerSignal" ) {
#############################
# ROTARY1 PUMP #
#############################
record( bo, "$(P)$(R)RotatoryPump" ) {
record( bo, "$(P)$(R)RPump1-Motor" ) {
# field(DESC," Liga a alimentação da bomba rotatória 1 ")
#record( bo, "$(P)$(R)RotatoryPump" ) {
field( OUT, "$(P)$(R)PCF8574:60:REGISTER.B0 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
@@ -188,7 +215,9 @@ record( bo, "$(P)$(R)RotatoryPump" ) {
#############################
# ROTARY1 VALVE #
#############################
record( bo, "$(P)$(R)RotatoryValve" ) {
record( bo, "$(P)$(R)RPump1-Valve" ) {
field(DESC," Abre a valvula da bomba rotatoria 1 ")
# record( bo, "$(P)$(R)RotatoryValve" ) {
field( OUT, "$(P)$(R)PCF8574:60:REGISTER.B1 PP" )
field( ZNAM, "Open" )
field( ONAM, "Closed" )
@@ -197,7 +226,9 @@ record( bo, "$(P)$(R)RotatoryValve" ) {
#############################
# ROTARY2 PUMP #
#############################
record( bo, "$(P)$(R)RotatoryPump2" ) {
record( bo, "$(P)$(R)RPump2-Motor" ) {
field(DESC," Liga a alimentacao da bomba rotatoria 2 ")
#record( bo, "$(P)$(R)RotatoryPump2" ) {
field( OUT, "$(P)$(R)PCF8574:60:REGISTER.B2 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
@@ -206,7 +237,9 @@ record( bo, "$(P)$(R)RotatoryPump2" ) {
#############################
# ROTARY2 VALVE #
#############################
record( bo, "$(P)$(R)RotatoryValve2" ) {
record( bo, "$(P)$(R)RPump2-Valve" ) {
field(DESC," Abre a valvula da bomba rotatoria 2 ")
#record( bo, "$(P)$(R)RotatoryValve2" ) {
field( OUT, "$(P)$(R)PCF8574:60:REGISTER.B3 PP" )
field( ZNAM, "Open" )
field( ONAM, "Closed" )
@@ -215,7 +248,9 @@ record( bo, "$(P)$(R)RotatoryValve2" ) {
################################
# FILAMENT ON/OFF #
################################
record(bo, "$(P)$(R)FilamentOnOff" ) {
record(bo, "$(P)$(R)VVessel-Filament" ) {
field(DESC," Filamento dentro do TOK para pre ionizar a câmara")
# record(bo, "$(P)$(R)FilamentOnOff" ) {
field( OUT, "$(P)$(R)PCF8574:60:REGISTER.B4 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
@@ -224,7 +259,9 @@ record(bo, "$(P)$(R)FilamentOnOff" ) {
##############################
# LIGHTS ON/OFF #
##############################
record(bo, "$(P)$(R)LightsOnOff" ) {
record(bo, "$(P)$(R)Lab-WarningLight" ) {
field(DESC," Luzes de sinalização, 220V ")
# record(bo, "$(P)$(R)LightsOnOff" ) {
field( OUT, "$(P)$(R)PCF8574:60:REGISTER.B5 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
@@ -238,7 +275,9 @@ record(bo, "$(P)$(R)LightsOnOff" ) {
##############################
# TOR CLEAN CONTACTOR ON/OFF #
##############################
record(bo, "$(P)$(R)ToroidalCleanContactorOnOff" ) {
record(bo, "$(P)$(R)Clean-TorContactor" ) {
# field(DESC," Contactor 220V do transformador para a fonte de campo toroidal das descargas de limpeza (500 A) ")
# record(bo, "$(P)$(R)ToroidalCleanContactorOnOff" ) {
field( OUT, "$(P)$(R)PCF8574:60:REGISTER.B7 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
@@ -253,25 +292,34 @@ record(bo, "$(P)$(R)ToroidalCleanContactorOnOff" ) {
############################
# TOR CLEAN BREAKER ON/OFF #
############################
record(bo, "$(P)$(R)ToroidalCleanBreakerOnOff" ) {
record(bo, "$(P)$(R)Clean-TorPneuBreaker" ) {
## field(DESC," Interruptor de ar comprimido do transformador para a fonte de campo toroidal das descargas de limpeza (500 A)")
#record(bo, "$(P)$(R)ToroidalCleanBreakerOnOff" ) {
field( OUT, "$(P)$(R)PCF8574:61:REGISTER.B0 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
}
record(bo, "$(P)$(R)ToroidalShotEnableOnOff" ) {
record(bo, "$(P)$(R)Shot-TorPSDisable" ) {
# field(DESC," É desligado na emergência e em qualquer estado que não seja Process ou Wait Shot.")
# record(bo, "$(P)$(R)ToroidalShotEnableOnOff" ) {
field( OUT, "$(P)$(R)PCF8574:61:REGISTER.B1 PP" )
field( ZNAM, "Off" )
field( ONAM, "On" )
}
record(bo, "$(P)$(R)ToroidalShotTriggerOnOff" ) {
record(bo, "$(P)$(R)Shot-TorPSTrigger" ) {
field(DESC," Trigger da FRAEP")
# record(bo, "$(P)$(R)ToroidalShotTriggerOnOff" ) {
field( ZNAM, "Off" )
field( ONAM, "Pulse" )
field( HIGH, "2.5")
field( FLNK, "$(P)$(R)ToroidalShotTriggerOnOffInv" )
field( FLNK, "$(P)$(R)Shot-TorPSTriggerInv" )
# field( FLNK, "$(P)$(R)ToroidalShotTriggerOnOffInv" )
}
record(calcout, "$(P)$(R)ToroidalShotTriggerOnOffInv" ) {
record(calcout, "$(P)$(R)Shot-TorPSTriggerInv" ) {
# field(DESC," $(R)")
#record(calcout, "$(P)$(R)ToroidalShotTriggerOnOffInv" ) {
field( INPA, "$(P)$(R)ToroidalShotTriggerOnOff NPP MS" )
field( OUT, "$(P)$(R)PCF8574:61:REGISTER.B2 PP MS" )
field( OOPT, "On Change" )
@@ -282,7 +330,9 @@ record(calcout, "$(P)$(R)ToroidalShotTriggerOnOffInv" ) {
#######################################
# CAP BANK CHARGE ON/OFF #
#######################################
record(bo, "$(P)$(R)CapBankChargeOnOff" ) {
record(bo, "$(P)$(R)CapBank-Charge" ) {
## field(DESC," Contactor 220V do circuito de carga do banco de condensadores p/ SHOT (ELCO) ")
#record(bo, "$(P)$(R)CapBankChargeOnOff" ) {
field( OUT, "$(P)$(R)PCF8574:61:REGISTER.B3 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
@@ -291,7 +341,9 @@ record(bo, "$(P)$(R)CapBankChargeOnOff" ) {
########################################
# PRIMARY CLEAN CONTACTOR ON/OFF #
########################################
record(bo, "$(P)$(R)PrimaryCleanContactorOnOff" ) {
record(bo, "$(P)$(R)Clean-PrimContactor" ) {
# field(DESC," Contactor 220V do para o primário das descargas de limpeza ")
# record(bo, "$(P)$(R)PrimaryCleanContactorOnOff" ) {
field( OUT, "$(P)$(R)PCF8574:61:REGISTER.B4 PP MS" )
field( ZNAM, "On" )
field( ONAM, "Off" )
@@ -300,7 +352,8 @@ record(bo, "$(P)$(R)PrimaryCleanContactorOnOff" ) {
####################################
### PRIMARY CLEAN BREAKER ON/OFF ###
####################################
record(bo, "$(P)$(R)PrimaryCleanBreakerOnOff"){
record(bo, "$(P)$(R)Clean-PrimPneuBreaker"){
#record(bo, "$(P)$(R)PrimaryCleanBreakerOnOff"){
field( DESC, "Primary Cleaning OnOff")
field( OUT, "$(P)$(R)PCF8574:61:REGISTER.B5 PP" )
field( ZNAM, "On")
@@ -310,7 +363,9 @@ record(bo, "$(P)$(R)PrimaryCleanBreakerOnOff"){
##################################
# GIS VALVES ON/OFF #
##################################
record(bo, "$(P)$(R)GISValvesOnOff" ) {
record(bo, "$(P)$(R)GasIS-Valves" ) {
# field(DESC," 2 válvulas pneumáticas de corte do sistema de injecção de H/D/Ne/He no TOK, 24V out = deixa passar")
# record(bo, "$(P)$(R)GISValvesOnOff" ) {
field( OUT, "$(P)$(R)PCF8574:61:REGISTER.B6 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
@@ -319,7 +374,9 @@ record(bo, "$(P)$(R)GISValvesOnOff" ) {
##########################################
# CAP BANK DISCHARGE ON/OFF #
##########################################
record(bo, "$(P)$(R)CapBankDischargeOnOff" ) {
record(bo, "$(P)$(R)CapBank-Discharge" ) {
field(DESC," Liga o circuito de descarga do ELCO ")
# record(bo, "$(P)$(R)CapBankDischargeOnOff" ) {
field( OUT, "$(P)$(R)PCF8574:61:REGISTER.B7 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
@@ -343,7 +400,9 @@ record(ai,"$(P)$(R)Bypass_Condition"){
field(VAL,"0")
}
record(ai,"$(P)$(R)Turbo2_Speed"){
record(ai,"$(P)$(R)TMPump2-Speed"){
# field(DESC," ADC Pump speed 0-10V ")
#record(ai,"$(P)$(R)Turbo2_Speed"){
field(PREC,"3")
field(EGU,"RPM")
field(VAL,"0")
@@ -352,7 +411,9 @@ record(ai,"$(P)$(R)Turbo2_Speed"){
#######################
###TMP1 Manual Valve###
#######################
record(bo, "$(P)$(R)TMPManualValve"){
record(bo, "$(P)$(R)TMPump1-ManualValve"){
# field(DESC," $(R)")
#record(bo, "$(P)$(R)TMPManualValve"){
info(autosaveFields, "VAL")
field( DESC, "State of manual valve")
field( ZNAM, "Closed")

View File

@@ -5,7 +5,7 @@ include $(TOP)/configure/CONFIG
# Install databases, templates & substitutions like this
DB += ISTTOKstates.db
DB += ISTTOKvacummPumps.db
DB += ISTTOKvacuumPumps.db
DB += ISTTOKpcf8574.db
DB += ISTTOKpcf8591.db
DB += ISTTOKpfeiffer.db

File diff suppressed because it is too large Load Diff