@@ -1,8 +1,8 @@
#############################################
## Project : ISTTOK slow Control
##
## File :
## Description : Records for ISTTOK Control I/O channels connected to 2 Velleman board
## File :
## Description : Records for ISTTOK Control I/O channels connected to 2 Velleman board
##
##
## Author : Bernardo Carvalho (IPFN-IST)
@@ -23,108 +23,103 @@
### 24V commands - Optocoupler Out###
#####################################
record(bo, "$(P)$(R)TMPump1-ControllerOn" ) {
# field(DESC,"Sinal p/ TMP 1, Liga a alimentação do controlador, vai a HIGH e depois a LO W")
# field( ZNAM, "Off" )record(bo, "$(P)$(R)TMPControllerOn" ) {
field(Z NAM, "Off " )
field(ONAM, "Pulse" )
field(HIGH, "2.5" )
field(FLNK, "$(P)$(R)TMPump1-ControllerOnInv" )
field(VAL,"0")
# field( FLNK, "$(P)$(R)TMPControllerOnInv" )
field(DESC,"Sig nal to TMP 1, goes HIGH and LW")
field(ZNAM, "Off" )
field(O NAM, "Pulse " )
field(HIGH, "2.5" )
field(FLNK, "$(P)$(R)TMPump1-ControllerOnInv" )
field(VAL,"0" )
}
record(calcout, "$(P)$(R)TMPump1-ControllerOnInv" ) {
#record(calcout , "$(P)$(R)TMPControllerOnInv" ) {
field( INPA, "$(P)$(R)TMPControllerOn N PP MS" )
field( OUT, "$(P)$(R)PCF8574:56:REGISTER.B0 PP MS" )
field( OOPT, "On Change" )
field( CALC, "A?0:1" )
record(calcout, "$(P)$(R)TMPump1-ControllerOnInv") {
field(INPA , "$(P)$(R)TMPump1- ControllerOn NPP MS")
field(OUT, "$(P)$(R)PCF8574:56:REGISTER.B0 PP MS")
field(OOPT, "On Change" )
field(CALC, "A?0:1" )
}
record(bo, "$(P)$(R)TMPump1-ControllerOff" ) {
# field(DESC," Sinal p/ TMP 1, desliga a alimentação do controlador, LOW->HIGH-> LOW")
# record(bo, "$(P)$(R)TMPControllerOff" ) {
field(ZNAM, "Off" )
field(ONAM, "Pulse" )
field(HIGH, "2.5")
# field( FLNK, "$(P)$(R)TMPControllerOffInv" )
field(FLNK, "$(P)$(R)TMPump1-ControllerOffInv" )
field(VAL,"0")
field(ZNAM, "Off" )
field(ONAM, "Pulse" )
field(HIGH, "2.5")
field(FLNK, "$(P)$(R)TMPump1- ControllerOffInv" )
field(VAL,"0" )
}
record(calcout, "$(P)$(R)TMPump1-ControllerOffInv") {
field( INPA, "$(P)$(R)TMPump1-ControllerOff NPP MS" )
field( OUT, "$(P)$(R)PCF8574:56:REGISTER.B1 PP MS")
field( OOPT, "On Change" )
field( CALC, "A?0:1" )
field(INPA, "$(P)$(R)TMPump1-ControllerOff NPP MS" )
field(OUT, "$(P)$(R)PCF8574:56:REGISTER.B1 PP MS")
field(OOPT, "On Change")
field(CALC, "A?0:1")
}
record(bo, "$(P)$(R)TMPump1-MotorOn" ) {
field( ZNAM, "Off")
field( ONAM, "Pulse")
field( HIGH, "2.5")
field( FLNK, "$(P)$(R)TMPump1-MotorOnInv")
field( ZNAM, "Off")
field( ONAM, "Pulse")
field( HIGH, "2.5")
field( FLNK, "$(P)$(R)TMPump1-MotorOnInv")
}
record(calcout, "$(P)$(R)TMPump1-MotorOnInv" ) {
field( INPA, "$(P)$(R)TMPump1-MotorOn NPP MS")
field( OUT, "$(P)$(R)PCF8574:56:REGISTER.B2 PP MS")
field( OOPT, "On Change")
field( CALC, "A?0:1" )
field( INPA, "$(P)$(R)TMPump1-MotorOn NPP MS")
field( OUT, "$(P)$(R)PCF8574:56:REGISTER.B2 PP MS")
field( OOPT, "On Change")
field( CALC, "A?0:1" )
}
record(bo, "$(P)$(R)TMPump1-MotorOff") {
field( ZNAM, "Off")
field( ONAM, "Pulse")
field( HIGH, "2.5")
field( FLNK, "$(P)$(R)TMPump1-MotorOffInv")
field(VAL,"0")
field( ZNAM, "Off")
field( ONAM, "Pulse")
field( HIGH, "2.5")
field( FLNK, "$(P)$(R)TMPump1-MotorOffInv")
field(VAL,"0")
}
record(calcout, "$(P)$(R)TMPump1-MotorOffInv") {
field( INPA, "$(P)$(R)TMPump1-MotorOff NPP MS")
field( OUT, "$(P)$(R)PCF8574:56:REGISTER.B3 PP MS")
field( OOPT, "On Change")
field( CALC, "A?0:1")
field( INPA, "$(P)$(R)TMPump1-MotorOff NPP MS")
field( OUT, "$(P)$(R)PCF8574:56:REGISTER.B3 PP MS")
field( OOPT, "On Change")
field( CALC, "A?0:1")
}
#############################
### TMP1 Controller inputs###
#############################
record(fanout, "$(P)$(R)PCF8574:56:REGISTER:READ:FNOUT"){
field(LNK1, "$(P)$(R)TMPump1-Power")
field(LNK2, "$(P)$(R)TMPump1-Emergency")
field(LNK3, "$(P)$(R)TMPump1-Acceleration")
field(LNK4, "$(P)$(R)TMPump1-NormalOperation")
field(LNK1, "$(P)$(R)TMPump1-Power")
field(LNK2, "$(P)$(R)TMPump1-Emergency")
field(LNK3, "$(P)$(R)TMPump1-Acceleration")
field(LNK4, "$(P)$(R)TMPump1-NormalOperation")
}
record(bi , "$(P)$(R)TMPump1-Power" ) {
field(DESC," TMP1 – Alimentada 220V ")
field( INP, "$(P)$(R)PCF8574:56:REGISTER:READ.B4 NPP NMS")
field( ZNAM, "ON" )
field( ONAM, "OFF" )
field(DESC," TMP1 – Alimentada 220V ")
field( INP, "$(P)$(R)PCF8574:56:REGISTER:READ.B4 NPP NMS")
field( ZNAM, "ON" )
field( ONAM, "OFF" )
}
record(bi , "$(P)$(R)TMPump1-Emergency") {
field(DESC," TMP1 – Falha ")
field( INP, "$(P)$(R)PCF8574:56:REGISTER:READ.B6 NPP NMS")
field(DESC," TMP1 – Falha ")
field( INP, "$(P)$(R)PCF8574:56:REGISTER:READ.B6 NPP NMS")
# field(VAL,"1")
field( ZNAM, "ON" )
field( ONAM, "OFF" )
field(ZSV,"MAJOR")
field( ZNAM, "ON" )
field( ONAM, "OFF" )
field(ZSV,"MAJOR")
}
record(bi , "$(P)$(R)TMPump1-Acceleration") {
field(DESC," TMP1 – Motor em aceleração ")
field( INP, "$(P)$(R)PCF8574:56:REGISTER:READ.B5 NPP NMS")
field( ZNAM, "ON" )
field( ONAM, "OFF" )
field(ZSV,"MINOR")
field(DESC," TMP1 – Motor em aceleração ")
field( INP, "$(P)$(R)PCF8574:56:REGISTER:READ.B5 NPP NMS")
field( ZNAM, "ON" )
field( ONAM, "OFF" )
field(ZSV,"MINOR")
}
record(bi , "$(P)$(R)TMPump1-NormalOperation" ) {
field(DESC," TMP1 – Operação Normal ")
field( INP, "$(P)$(R)PCF8574:56:REGISTER:READ.B7 NPP NMS")
field( ZNAM, "ON" )
field(ONAM, "OFF" )
field(OSV,"MINOR")
field(DESC," TMP1 – Operação Normal ")
field( INP, "$(P)$(R)PCF8574:56:REGISTER:READ.B7 NPP NMS")
field( ZNAM, "ON" )
field(ONAM, "OFF" )
field(OSV,"MINOR")
}
###############
@@ -137,87 +132,87 @@ record(bi , "$(P)$(R)TMPump1-NormalOperation" ) {
### TMP2 Controller Inputs ###
##############################
record(fanout, "$(P)$(R)PCF8574:57:REGISTER:READ:FNOUT"){
field(LNK1, "$(P)$(R)TMPump2-Emergency")
field(LNK2, "$(P)$(R)TMPump2-Acceleration")
field(LNK3, "$(P)$(R)TTSystem-tzero")
field(LNK4, "$(P)$(R)Emergency-PhysButton")
field(LNK1, "$(P)$(R)TMPump2-Emergency")
field(LNK2, "$(P)$(R)TMPump2-Acceleration")
field(LNK3, "$(P)$(R)TTSystem-tzero")
field(LNK4, "$(P)$(R)Emergency-PhysButton")
}
record(bi , "$(P)$(R)TMPump2-Emergency") {
field(DESC," TMP2 – Falha ")
field(DESC," TMP2 – Falha ")
# field(INP, "$(P)$(R)PCF8574:57:REGISTER:READ.B0 NPP NMS")
field(VAL,"1")
field(ZNAM, "ON" )
field(ONAM, "OFF" )
field(ZSV,"MAJOR")
field(VAL,"1")
field(ZNAM, "ON" )
field(ONAM, "OFF" )
field(ZSV,"MAJOR")
}
record(bi , "$(P)$(R)TMPump2-Acceleration") {
field(DESC," TMP2 – START until Normal ")
field( INP, "$(P)$(R)PCF8574:57:REGISTER:READ.B1 NPP NMS")
field( ZNAM, "ON" )
field( ONAM, "OFF" )
field(DESC," TMP2 – START until Normal ")
field( INP, "$(P)$(R)PCF8574:57:REGISTER:READ.B1 NPP NMS")
field( ZNAM, "ON" )
field( ONAM, "OFF" )
}
####################################
# TIMING TRIGGER ON/OFF #
####################################
record(bi , "$(P)$(R)TTSystem-tzero" ) {
field(DESC,"Trigger control 60s before shot")
field(INP, "$(P)$(R)PCF8574:57:REGISTER:READ.B7")
field(DESC,"Trigger control 60s before shot")
field(INP, "$(P)$(R)PCF8574:57:REGISTER:READ.B7")
# field(VAL,"1")
field(ZNAM, "OFF" )
field(ONAM, "ON" )
field(ZNAM, "OFF" )
field(ONAM, "ON" )
}
###############################
### TMP2 Controller Outputs ###
###############################
record(bo, "$(P)$(R)TMPump2-Motor" ) {
field(DESC," Motor On/Off ")
field(DESC," Motor On/Off ")
# record(bo, "$(P)$(R)TMP2MotorOnOff" ) {
field( OUT, "$(P)$(R)PCF8574:57:REGISTER.B2 PP MS")
field( ZNAM, "ON")
field( ONAM, "OFF")
field( OUT, "$(P)$(R)PCF8574:57:REGISTER.B2 PP MS")
field( ZNAM, "ON")
field( ONAM, "OFF")
}
##############################
# BUZZER ON/OFF #
##############################
record(bo, "$(P)$(R)Buzzer" ) {
field(DESC," Lab Buzzer ")
field(ZNAM, "Off" )
field(ONAM, "Pulse" )
field(HIGH, "2.5")
field(FLNK, "$(P)$(R)BuzzerInv" )
field(VAL, "0")
field(DESC," Lab Buzzer ")
field(ZNAM, "Off" )
field(ONAM, "Pulse" )
field(HIGH, "2.5")
field(FLNK, "$(P)$(R)BuzzerInv" )
field(VAL, "0")
}
record(calcout, "$(P)$(R)BuzzerInv" ) {
field(INPA, "$(P)$(R)Buzzer NPP MS" )
field(OUT, "$(P)$(R)PCF8574:57:REGISTER.B3 PP MS" )
field(OOPT, "On Change" )
field(CALC, "A?0:1" )
field(INPA, "$(P)$(R)Buzzer NPP MS" )
field(OUT, "$(P)$(R)PCF8574:57:REGISTER.B3 PP MS" )
field(OOPT, "On Change" )
field(CALC, "A?0:1" )
}
##############################
# EMERGENCY MODE #
##############################
record(bi, "$(P)$(R)Emergency-PhysButton" ) {
field(DESC,"External Physical Emergency Button")
field(INP, "$(P)$(R)PCF8574:57:REGISTER:READ.B4 NPP NMS")
field(ZNAM, "ON")
field(ONAM, "OFF" )
field(FLNK, "$(P)$(R)Emergency" )
field(DESC,"External Physical Emergency Button")
field(INP, "$(P)$(R)PCF8574:57:REGISTER:READ.B4 NPP NMS")
field(ZNAM, "ON")
field(ONAM, "OFF" )
field(FLNK, "$(P)$(R)Emergency" )
}
record(bo, "$(P)$(R)Emergency-UserButton" ) {
field(DESC,"Soft User Emergency Button")
field(ZNAM, "OFF" )
field(ONAM, "ON")
field(FLNK, "$(P)$(R)Emergency" )
field(DESC,"Soft User Emergency Button")
field(ZNAM, "OFF" )
field(ONAM, "ON")
field(FLNK, "$(P)$(R)Emergency" )
}
record(calc, "$(P)$(R)Emergency" ) {
field(DESC, "Emergency State")
field(INPA, "$(P)$(R)Emergency-PhysButton.RVAL NPP" )
field(INPB, "$(P)$(R)Emergency-UserButton.RVAL NPP" )
field(CALC, "A || B" ) # ! Not
field(DESC, "Emergency State")
field(INPA, "$(P)$(R)Emergency-PhysButton.RVAL NPP" )
field(INPB, "$(P)$(R)Emergency-UserButton.RVAL NPP" )
field(CALC, "A || B" ) # ! Not
}
############
@@ -237,71 +232,71 @@ record(calc, "$(P)$(R)Emergency" ) {
# ROTARY1 PUMP #
#############################
record( bo, "$(P)$(R)RPump1-Motor" ) {
field(DESC,"Power to Rotatory Pump 1. Relay 5")
field(OUT, "$(P)$(R)PCF8574:60:REGISTER.B0 PP" )
field(ZNAM, "Off" )
field(ONAM, "On" )
field(VAL,"1")
field(ZSV,"MINOR")
field(DESC,"Power to Rotatory Pump 1. Relay 5")
field(OUT, "$(P)$(R)PCF8574:60:REGISTER.B0 PP" )
field(ZNAM, "Off" )
field(ONAM, "On" )
field(VAL,"1")
field(ZSV,"MINOR")
}
#############################
# ROTARY1 VALVE #
#############################
record( bo, "$(P)$(R)RPump1-Valve" ) {
field(DESC,"Abre a valvula da bomba rot. Relay 4")
field(OUT, "$(P)$(R)PCF8574:60:REGISTER.B1 PP" )
field(ZNAM, "Closed" )
field(ONAM, "Open" )
field(VAL,"1")
field(DESC,"Abre a valvula da bomba rot. Relay 4")
field(OUT, "$(P)$(R)PCF8574:60:REGISTER.B1 PP" )
field(ZNAM, "Closed" )
field(ONAM, "Open" )
field(VAL,"1")
}
#############################
# ROTARY2 PUMP #
#############################
record( bo, "$(P)$(R)RPump2-Motor" ) {
field(DESC,"Power On Rotatory Pump 2")
field(OUT, "$(P)$(R)PCF8574:60:REGISTER.B2 PP" )
field(ZNAM, "Off" )
field(ONAM, "On" )
field(VAL,"1")
field(ZSV,"MINOR")
field(DESC,"Power On Rotatory Pump 2")
field(OUT, "$(P)$(R)PCF8574:60:REGISTER.B2 PP" )
field(ZNAM, "Off" )
field(ONAM, "On" )
field(VAL,"1")
field(ZSV,"MINOR")
}
#############################
# ROTARY2 VALVE #
#############################
record( bo, "$(P)$(R)RPump2-Valve" ) {
field(DESC," Abre a valvula da bomba rotatoria 2 ")
field(OUT,"$(P)$(R)PCF8574:60:REGISTER.B3 PP" )
field(ZNAM,"Closed" )
field(ONAM,"Open" )
field(VAL,"1")
field(DESC," Abre a valvula da bomba rotatoria 2 ")
field(OUT,"$(P)$(R)PCF8574:60:REGISTER.B3 PP" )
field(ZNAM,"Closed" )
field(ONAM,"Open" )
field(VAL,"1")
}
################################
# FILAMENT ON/OFF #
################################
record(bo, "$(P)$(R)VVessel-Filament" ) {
field(DESC,"Vacuum Vessel Filament power")
field(DESC,"Vacuum Vessel Filament power")
# record(bo, "$(P)$(R)FilamentOnOff" ) {
field( OUT, "$(P)$(R)PCF8574:60:REGISTER.B4 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
field(VAL,"1")
field(PINI,"YES")
field( OUT, "$(P)$(R)PCF8574:60:REGISTER.B4 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
field(VAL,"1")
field(PINI,"YES")
}
##############################
# LIGHTS ON/OFF #
##############################
record(bo, "$(P)$(R)Lab-WarningLight" ) {
field(DESC," Luzes de sinalização, 220V ")
field(DESC," Luzes de sinalização, 220V ")
# record(bo, "$(P)$(R)LightsOnOff" ) {
field(OUT, "$(P)$(R)PCF8574:60:REGISTER.B5 PP" )
field(ZNAM, "On" )
field(ONAM, "Off" )
field(VAL,"1")
field(OUT, "$(P)$(R)PCF8574:60:REGISTER.B5 PP" )
field(ZNAM, "On" )
field(ONAM, "Off" )
field(VAL,"1")
}
############
@@ -314,10 +309,10 @@ record(bo, "$(P)$(R)Lab-WarningLight" ) {
##############################
record(bo, "$(P)$(R)Clean-TorContactor" ) {
# field(DESC," Contactor 220V do transformador para a fonte de campo toroidal das descargas de limpeza (500 A) ")
field( OUT, "$(P)$(R)PCF8574:60:REGISTER.B7 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
field(VAL,"1")
field( OUT, "$(P)$(R)PCF8574:60:REGISTER.B7 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
field(VAL,"1")
}
###############
@@ -331,34 +326,34 @@ record(bo, "$(P)$(R)Clean-TorContactor" ) {
############################
record(bo, "$(P)$(R)Clean-TorPneuBreaker" ) {
## field(DESC," Interruptor de ar comprimido do transformador para a fonte de campo toroidal das descargas de limpeza (500 A)")
field( OUT, "$(P)$(R)PCF8574:61:REGISTER.B0 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
field(VAL,"1")
field( OUT, "$(P)$(R)PCF8574:61:REGISTER.B0 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
field(VAL,"1")
}
record(bo, "$(P)$(R)Shot-TorPSDisable" ) {
# field(DESC," É desligado na emergência e em qualquer estado que não seja Process ou Wait Shot.")
field( OUT, "$(P)$(R)PCF8574:61:REGISTER.B1 PP" )
field( ZNAM, "Off" )
field( ONAM, "On" )
field(VAL,"1")
field( OUT, "$(P)$(R)PCF8574:61:REGISTER.B1 PP" )
field( ZNAM, "Off" )
field( ONAM, "On" )
field(VAL,"1")
}
record(bo, "$(P)$(R)Shot-TorPSTrigger" ) {
field(DESC," Trigger da FRAEP")
field( ZNAM, "Off" )
field( ONAM, "Pulse" )
field( HIGH, "2.5")
field( FLNK, "$(P)$(R)Shot-TorPSTriggerInv" )
field(VAL,"0")
field(DESC," Trigger da FRAEP")
field( ZNAM, "Off" )
field( ONAM, "Pulse" )
field( HIGH, "2.5")
field( FLNK, "$(P)$(R)Shot-TorPSTriggerInv" )
field(VAL,"0")
}
record(calcout, "$(P)$(R)Shot-TorPSTriggerInv" ) {
# field(DESC," $(R)")
field( INPA, "$(P)$(R)ToroidalShotTriggerOnOff NPP MS" )
field( OUT, "$(P)$(R)PCF8574:61:REGISTER.B2 PP MS" )
field( OOPT, "On Change" )
field( CALC, "A?0:1" )
field( INPA, "$(P)$(R)ToroidalShotTriggerOnOff NPP MS" )
field( OUT, "$(P)$(R)PCF8574:61:REGISTER.B2 PP MS" )
field( OOPT, "On Change" )
field( CALC, "A?0:1" )
}
############################################################
@@ -368,10 +363,10 @@ record(calcout, "$(P)$(R)Shot-TorPSTriggerInv" ) {
record(bo, "$(P)$(R)CapBank-Charge" ) {
## field(DESC," Contactor 220V do circuito de carga do banco de condensadores p/ SHOT (ELCO) ")
#record(bo, "$(P)$(R)CapBankChargeOnOff" ) {
field(OUT, "$(P)$(R)PCF8574:61:REGISTER.B3 PP" )
field(ZNAM, "On" )
field(ONAM, "Off" )
field(VAL,"1")
field(OUT, "$(P)$(R)PCF8574:61:REGISTER.B3 PP" )
field(ZNAM, "On" )
field(ONAM, "Off" )
field(VAL,"1")
}
########################################
@@ -380,10 +375,10 @@ record(bo, "$(P)$(R)CapBank-Charge" ) {
record(bo, "$(P)$(R)Clean-PrimContactor" ) {
# field(DESC," Contactor 220V do para o primário das descargas de limpeza ")
# record(bo, "$(P)$(R)PrimaryCleanContactorOnOff" ) {
field(OUT, "$(P)$(R)PCF8574:61:REGISTER.B4 PP MS" )
field(ZNAM, "On" )
field(ONAM, "Off" )
field(VAL,"1")
field(OUT, "$(P)$(R)PCF8574:61:REGISTER.B4 PP MS" )
field(ZNAM, "On" )
field(ONAM, "Off" )
field(VAL,"1")
}
####################################
@@ -391,11 +386,11 @@ record(bo, "$(P)$(R)Clean-PrimContactor" ) {
####################################
record(bo, "$(P)$(R)Clean-PrimPneuBreaker"){
#record(bo, "$(P)$(R)PrimaryCleanBreakerOnOff"){
field( DESC, "Primary Cleaning OnOff")
field( OUT, "$(P)$(R)PCF8574:61:REGISTER.B5 PP" )
field( ZNAM, "On")
field( ONAM, "Off")
field(VAL,"1")
field( DESC, "Primary Cleaning OnOff")
field( OUT, "$(P)$(R)PCF8574:61:REGISTER.B5 PP" )
field( ZNAM, "On")
field( ONAM, "Off")
field(VAL,"1")
}
##################################
@@ -404,22 +399,22 @@ record(bo, "$(P)$(R)Clean-PrimPneuBreaker"){
record(bo, "$(P)$(R)GasIS-Valves" ) {
# field(DESC," 2 válvulas pneumáticas de corte do sistema de injecção de H/D/Ne/He no TOK, 24V out = deixa passar")
# record(bo, "$(P)$(R)GISValvesOnOff" ) {
field( OUT, "$(P)$(R)PCF8574:61:REGISTER.B6 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
field(VAL,"1")
field( OUT, "$(P)$(R)PCF8574:61:REGISTER.B6 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
field(VAL,"1")
}
##########################################
# CAP BANK DISCHARGE ON/OFF #
##########################################
record(bo, "$(P)$(R)CapBank-Discharge" ) {
field(DESC," Liga o circuito de descarga do ELCO ")
field(DESC," Liga o circuito de descarga do ELCO ")
# record(bo, "$(P)$(R)CapBankDischargeOnOff" ) {
field(OUT, "$(P)$(R)PCF8574:61:REGISTER.B7 PP" )
field(ZNAM, "On" )
field(ONAM, "Off" )
field(VAL,"1")
field(OUT, "$(P)$(R)PCF8574:61:REGISTER.B7 PP" )
field(ZNAM, "On" )
field(ONAM, "Off" )
field(VAL,"1")
}
#record(bo,"$(P)$(R)Primary-PressureCondition"){
@@ -431,9 +426,9 @@ record(bo, "$(P)$(R)CapBank-Discharge" ) {
record(ai,"$(P)$(R)TMPump2-Speed"){
# field(DESC," ADC Pump speed 0-10V ")
#record(ai,"$(P)$(R)Turbo2_Speed"){
field(PREC,"3")
field(EGU,"RPM")
field(VAL,"0")
field(PREC,"3")
field(EGU,"RPM")
field(VAL,"0")
}
#######################
@@ -442,8 +437,8 @@ record(ai,"$(P)$(R)TMPump2-Speed"){
record(bo, "$(P)$(R)TMPump1-ManualValve"){
# field(DESC," $(R)")
#record(bo, "$(P)$(R)TMPManualValve"){
info(autosaveFields, "VAL")
field( DESC, "State of manual valve")
field( ZNAM, "Closed")
field( ONAM, "Open")
info(autosaveFields, "VAL")
field( DESC, "State of manual valve")
field( ZNAM, "Closed")
field( ONAM, "Open")
}