Imported files from METIS SVN

This commit is contained in:
Bernardo Carvalho
2019-10-09 10:59:54 +01:00
parent 61d1517c44
commit 70c9ee4b76
473 changed files with 10804 additions and 0 deletions

View File

@@ -0,0 +1,95 @@
#######################################################
# ### ### #
# ### EPICS Database for ### #
# ### I2C PCF8574 board ### #
# ### ### #
# ### author: B. Carvalho IPFN ### #
# ### ### #
# ### Ref 2.0; 2018-01-14 ### #
# ### ### #
# ### macros: ID I2C address of ADC ### #
# ### Description: ### #
# ### This is an example DB file using ### #
# ### stream(asynI2C) and to read/write ### #
# ### an PCF8574 ### #
#######################################################
#####################################################
# ### Read/Write pcf8574 address 0x38=56 register ### #
###################################################
record( mbboDirect, "$(P)$(R)PCF8574:56:REGISTER") {
field( DTYP, "stream")
field( OUT, "@pcf8574.proto wReg(56) I2C")
field( SHFT, "0")
field( NOBT, "8")
field(VAL, 255)
field(PINI,"YES")
}
record( mbbiDirect, "$(P)$(R)PCF8574:56:REGISTER:READ" ) {
field( DTYP, "stream")
field( INP, "@pcf8574.proto rReg(56) I2C")
field(NOBT, "8")
field(SCAN, "1 second")
field(PINI,"YES")
}
#####################################################
# ### Read/Write pcf8574 address 0x39=57 register ### #
###################################################
record( mbboDirect, "$(P)$(R)PCF8574:57:REGISTER") {
field( DTYP, "stream")
field( OUT, "@pcf8574.proto wReg(57) I2C")
field( SHFT, "0")
field( NOBT, "8")
field(VAL, 255)
field(PINI,"YES")
}
record( mbbiDirect, "$(P)$(R)PCF8574:57:REGISTER:READ" ) {
field( DTYP, "stream")
field( INP, "@pcf8574.proto rReg(57) I2C")
field(NOBT, "8")
field(SCAN, "1 second")
field(PINI,"YES")
}
#####################################################
# ### Read/Write pcf8574 address 0x3c=60 register ### #
###################################################
record( mbboDirect, "$(P)$(R)PCF8574:60:REGISTER") {
field( DTYP, "stream")
field( OUT, "@pcf8574.proto wReg(60) I2C")
field( SHFT, "0")
field( NOBT, "8")
field(VAL, 255)
field(PINI,"YES")
}
record( mbbiDirect, "$(P)$(R)PCF8574:60:REGISTER:READ" ) {
field( DTYP, "stream")
field( INP, "@pcf8574.proto rReg(60) I2C")
field(NOBT, "8")
field(SCAN, "1 second")
field(PINI,"YES")
}
#####################################################
# ### Read/Write pcf8574 address 0x3d=61 register ### #
###################################################
record( mbboDirect, "$(P)$(R)PCF8574:61:REGISTER") {
field( DTYP, "stream")
field( OUT, "@pcf8574.proto wReg(61) I2C")
field( SHFT, "0")
field( NOBT, "8")
field(VAL, 255)
field(PINI,"YES")
}
record( mbbiDirect, "$(P)$(R)PCF8574:61:REGISTER:READ" ) {
field( DTYP, "stream")
field( INP, "@pcf8574.proto rReg(61) I2C")
field(NOBT, "8")
field(SCAN, "1 second")
field(PINI,"YES")
}

View File

@@ -0,0 +1,49 @@
record (longin, "$(P)$(R)P003:M")
{
field (DESC, "getPressure003 Mantissa $(bus)")
field (DTYP, "stream")
field (INP, "@pfeiffer.proto getPressure003($(P)$(R)P003:E) $(bus)")
field (SCAN, "I/O Intr")
field (FLNK, "$(P)$(R)P003")
}
record (longin, "$(P)$(R)P003:E")
{
field (DESC, "Pressure003 Exponent $(bus)")
}
record (calc, "$(P)$(R)P003")
{
field(INPA, "$(P)$(R)P003:M")
field(INPB, "$(P)$(R)P003:E")
field(CALC, "(A*0.001)* 10.0**(B-20)")
field(PREC, "3")
field(EGU, "mBar")
}
record (longin, "$(P)$(R)P002:M")
{
field (DESC, "getPressure002 $(bus)")
field (DTYP, "stream")
field (INP, "@pfeiffer.proto getPressure002($(P)$(R)P002:E) $(bus)")
field (SCAN, "I/O Intr")
field (FLNK, "$(P)$(R)P002")
}
record (longin, "$(P)$(R)P002:E")
{
field (DESC, "Pressure002 exponent $(bus)")
}
record (calc, "$(P)$(R)P002")
{
field(INPA, "$(P)$(R)P002:M")
field(INPB, "$(P)$(R)P002:E")
field(CALC, "(A*0.001)*10.0**(B-20)")
field(PREC, "3")
field(EGU, "mBar")
}
record(stringout,"$(P)$(R)Debug") {
field(DESC, "")
field(DTYP, "stream")
field(OUT, "@pfeiffer.proto debug $(bus)")
field(VAL,"")
}

View File

@@ -0,0 +1,276 @@
#
# Project : ISTTOK slow Control
#
# File : $Id: ISTTOKcontrol.db 4709 2013-05-03 13:44:29Z bernardo $
# Description : Records for ISTTOK Control
#
##
# Author : Bernardo Carvalho (IPFN-IST)
#
# Copyright (c) : (IPFN-IST)
# Created 3-Mar-2013
#
# SVN keywords
# $Date: 2013-05-03 14:44:29 +0100 (Fri, 03 May 2013) $
# $Revision: 4709 $
# $URL: http://metis.ipfn.ist.utl.pt/svn/cdaq/ISTTOK/Software/EPICS/ISTTOKcontrol/trunk/ISTTOKApp/Db/ISTTOKcontrol.db $
##
record(mbbi, "$(P)$(R)OPSTATE") {
field(DESC, "Multiple Pulse Sequence State")
field(ZRVL, "0")
field(ONVL, "1")
field(TWVL, "2")
field(THVL, "3")
field(FRVL, "4")
field(FVVL, "5")
field(SXVL, "6")
field(ZRST, "Stopped")
field(ONST, "Starting")
field(TWST, "Process")
field(THST, "Clean")
field(FRST, "WaitShot")
field(FVST, "Stopping")
field(SXST, "Emergency")
field(VAL, "0")
}
record(calc, "$(P)$(R)OPCALCSTATE") {
field(DESC, "Pulse Calculated State")
field(CALC,"2^A")
field(SCAN,"1 second")
field(INPA,"$(P)$(R)OPSTATE.VAL PP NMS")
}
record(calc, "$(P)$(R)OPCALCSTARTSTATE") {
field(DESC, "Start Calculated State")
field(CALC,"2^A")
field(SCAN,"1 second")
field(INPA,"$(P)$(R)STARTINGSTATE.VAL PP NMS")
}
record(calc, "$(P)$(R)OPCALCSTOPSTATE") {
field(DESC, "Stop Calculated State")
field(CALC,"2^A")
field(SCAN,"1 second")
field(INPA,"$(P)$(R)STOPPINGSTATE.VAL PP NMS")
}
record(calc, "$(P)$(R)OPCALCACLEANSTATE") {
field(DESC, "Clean Automatic Calculated State")
field(CALC,"(2^(A+1))-1")
field(SCAN,"1 second")
field(INPA,"$(P)$(R)CLEANINGSTATE.VAL PP NMS")
}
record(calc, "$(P)$(R)OPCALCMCLEANSTATE") {
field(DESC, "Clean Manual Calculated State")
field(CALC,"2^A")
field(SCAN,"1 second")
field(INPA,"$(P)$(R)CLEANINGSTATE.VAL PP NMS")
}
record(calc, "$(P)$(R)OPCALCWSHOTSTATE") {
field(DESC, "WaitShot Calculated State")
field(CALC,"2^A")
field(SCAN,"1 second")
field(INPA,"$(P)$(R)WSHOTINGSTATE.VAL PP NMS")
}
record(ai, "$(P)$(R)Temperature_0") {
field(DESC, "ISTTOK Temperature 0 Calculated")
field(EGU, "C")
field(SCAN,"1 second")
}
record(bo, "$(P)$(R)OPREQ") {
field(DESC, "Pulse Sequence Start/Stop")
field(VAL, "0")
field(ZNAM, "STOP")
field(ONAM, "START")
}
record(bo, "$(P)$(R)CLEANINGMASTATE") {
field(DESC, "Cleaning Manual/Auto")
field(VAL, "1")
field(ZNAM, "M")
field(ONAM, "A")
}
record(ai, "$(P)$(R)CLEANINGINOUTSTATE") {
field(DESC, "Cleaning Automatic In/Out")
field(VAL, "1")
}
record(ai, "$(P)$(R)CLEANINGINOUTSTATE0") {
field(DESC, "Cleaning Automatic In/Out")
field(VAL, "-2")
}
record(ai, "$(P)$(R)CLEANINGINOUTSTATE1") {
field(DESC, "Cleaning Automatic In/Out")
field(VAL, "-2")
}
record(ai, "$(P)$(R)CLEANINGINOUTSTATE2") {
field(DESC, "Cleaning Automatic In/Out")
field(VAL, "-2")
}
record(ai, "$(P)$(R)CLEANINGINOUTSTATE3") {
field(DESC, "Cleaning Automatic In/Out")
field(VAL, "-2")
}
record(ai, "$(P)$(R)CLEANINGINOUTSTATE4") {
field(DESC, "Cleaning Automatic In/Out")
field(VAL, "-2")
}
record(ai, "$(P)$(R)CLEANINGINOUTSTATE5") {
field(DESC, "Cleaning Automatic In/Out")
field(VAL, "-2")
}
record(bo, "$(P)$(R)FSTriggerState") {
field(DESC, "FireSignal Trigger Start")
field(VAL, "0")
field(ZNAM, "STOP")
field(ONAM, "START")
}
record(bo, "$(P)$(R)PROCESS-MODE") {
info(autosaveFields, "VAL")
field(DESC, "Plasma Process Mode")
#field(VAL, "0")
field(ZNAM, "CLEAN")
field(ONAM, "SHOT")
}
record(bo, "$(P)$(R)PROCESS-REQ") {
field(DESC, "Plasma Process sub-states Start/Stop")
field(VAL, "0")
field(ZNAM, "STOP")
field(ONAM, "START")
}
record(bo, "$(P)$(R)AUTHORISATION") {
field(DESC, "Pulse Sequence Authorisation Start/Abort")
field(ZNAM, "ABORT")
field(ONAM, "START")
field(VAL, "0")
}
record(longout, "$(P)$(R)PULSE-NUMBER") {
info(autosaveFields, "VAL")
field(DESC, "Pulse Number")
}
record(calc, "$(P)$(R)COUNTDOWN") {
field(DESC, "Countdown Increment")
field(INPA,"$(P)$(R)COUNTDOWN")
field(SCAN,"Passive")
field(CALC,"A+1")
field(VAL, "160")
}
record(calc, "$(P)$(R)COUNTER") {
field(DESC, "0.1 s counter")
field(INPA, "$(P)$(R)COUNTER")
field(SCAN, ".1 second")
field(CALC, "A + .1")
}
record(stringin, "$(P)$(R)CurrentTime") {
field(DESC, "Current Date and Time of the IOC")
field(SCAN, "1 second")
field(DTYP, "Soft Timestamp")
field(PINI, "YES")
field(INP, "@%d/%m/%Y %H:%M:%S")
}
record(stringout, "$(P)$(R)TraceMessage") {
field(DESC, "Trace Message from IOC")
field(VAL, "Trace mode ON")
}
record(mbbi, "$(P)$(R)STARTINGSTATE") {
field(DESC, "Starting State Sequence")
field(ZRVL, "0")
field(ONVL, "1")
field(TWVL, "2")
field(THVL, "3")
field(FRVL, "4")
field(FVVL, "5")
field(ZRST, "NonStarting")
field(ONST, "Starting1")
field(TWST, "Starting2")
field(THST, "Starting3")
field(FRST, "Starting4")
field(FVST, "Starting5")
field(VAL, "0")
}
record(mbbi, "$(P)$(R)STOPPINGSTATE") {
field(DESC, "Stopping State Sequence")
field(ZRVL, "0")
field(ONVL, "1")
field(TWVL, "2")
field(THVL, "3")
field(FRVL, "4")
field(FVVL, "5")
field(ZRST, "NonStopped")
field(ONST, "Stopping1")
field(TWST, "Stopping2")
field(THST, "Stopping3")
field(FRST, "Stopping4")
field(FVST, "Stopping5")
field(VAL, "0")
}
record(mbbi, "$(P)$(R)CLEANINGSTATE") {
field(DESC, "Cleaning State Sequence")
field(ZRVL, "0")
field(ONVL, "1")
field(TWVL, "2")
field(THVL, "3")
field(FRVL, "4")
field(FVVL, "5")
field(ZRST, "NonCleaning")
field(ONST, "Cleaning1")
field(TWST, "Cleaning2")
field(THST, "Cleaning3")
field(FRST, "Cleaning4")
field(FVST, "Cleaning5")
field(VAL, "0")
}
record(mbbi, "$(P)$(R)WSHOTINGSTATE") {
field(DESC, "Shoting State Sequence")
field(ZRVL, "0")
field(ONVL, "1")
field(TWVL, "2")
field(THVL, "3")
field(FRVL, "4")
field(FVVL, "5")
field(SXVL, "6")
field(SVVL, "7")
field(EIVL, "8")
field(NIVL, "9")
field(TEVL, "10")
field(ELVL, "11")
field(ZRST, "NonShoting")
field(ONST, "Shoting1")
field(TWST, "Shoting2")
field(THST, "Shoting3")
field(FRST, "Shoting4")
field(FVST, "Shoting5")
field(SXST, "Shoting6")
field(SVST, "Shoting7")
field(EIST, "Shoting8")
field(NIST, "Shoting9")
field(TEST, "Shoting10")
field(ELST, "Shoting11")
field(VAL, "0")
}

View File

@@ -0,0 +1,386 @@
##########
# Relays #
##########
record( bo, "$(P)$(R)RotatoryPump" ) {
field( OUT, "$(P)$(R)PCF8574:60:REGISTER.B7 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
}
record( bo, "$(P)$(R)RotatoryValve" ) {
field( OUT, "$(P)$(R)PCF8574:60:REGISTER.B6 PP" )
field( ZNAM, "Open" )
field( ONAM, "Closed" )
}
##############################
# BUZZER ON/OFF #
##############################
record(bo, "$(P)$(R)BuzzerOnOff" ) {
field( ZNAM, "Off" )
field( ONAM, "Pulse" )
field( HIGH, "2.5")
field( FLNK, "$(P)$(R)BuzzerOnOffInv" )
}
record(calcout, "$(P)$(R)BuzzerOnOffInv" ) {
field( INPA, "$(P)$(R)BuzzerOnOff NPP MS" )
#field( OUT, "$(P)$(R)PCF8574:60:REGISTER.B5 PP MS" )
field( OUT, "$(P)$(R)PCF8574:57:REGISTER.B5 PP MS" )
field( OOPT, "On Change" )
field( CALC, "A?0:1" )
}
##############################
# LIGHTS ON/OFF #
##############################
record(bo, "$(P)$(R)LightsOnOff" ) {
field( OUT, "$(P)$(R)PCF8574:60:REGISTER.B4 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
}
record(bi , "$(P)$(R)LightsOnOff-G" ) {
field( INP, "$(P)$(R)PCF8574:60:REGISTER:READ.B4 NPP NMS")
field( SCAN, "1 second")
field( ZNAM, "ON" )
field( ONAM, "OFF" )
}
##################################
# GIS VALVES ON/OFF #
##################################
record(bo, "$(P)$(R)GISValvesOnOff" ) {
#field( OUT, "$(P)$(R)PCF8574:60:REGISTER.B3 PP" )
field( OUT, "$(P)$(R)PCF8574:57:REGISTER.B4 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
}
################################
# FILAMENT ON/OFF #
################################
record(bo, "$(P)$(R)FilamentOnOff" ) {
field( OUT, "$(P)$(R)PCF8574:60:REGISTER.B2 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
}
##########################################
# CAP BANK CONNECTOR ON/OFF #
##########################################
record(bo, "$(P)$(R)CapBankConOnOff" ) {
#field( OUT, "$(P)$(R)PCF8574:60:REGISTER.B1 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
}
###############################
### PRIMARY CLEANING ON/OFF ###
###############################
record(bo, "$(P)$(R)PrimaryCleaningOnOff"){
field( DESC, "Primary Cleaning OnOff")
field( OUT, "$(P)$(R)PCF8574:60:REGISTER.B1 PP" )
field( ZNAM, "On")
field( ONAM, "Off")
}
#######################################
# CAP BANK CHARGE ON/OFF #
#######################################
record(bo, "$(P)$(R)CapBankChargeOnOff" ) {
field( OUT, "$(P)$(R)PCF8574:60:REGISTER.B0 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
}
####################################
# TIMING TRIGGER ON/OFF #
####################################
record(bi , "$(P)$(R)TimingTriggerSignal" ) {
field( INP, "$(P)$(R)PCF8574:57:REGISTER:READ.B7")
field( SCAN, "1 second" )
field( ZNAM, "OFF" )
field( ONAM, "ON" )
}
##########################################
# CAP BANK DISCHARGE ON/OFF #
##########################################
record(bo, "$(P)$(R)CapBankDischargeOnOff" ) {
field( OUT, "$(P)$(R)PCF8574:57:REGISTER.B6 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
}
##################################
# PPS BAKING ON/OFF #
##################################
record(bo, "$(P)$(R)BakingPPSOnOff" ) {
#field( OUT, "$(P)$(R)PCF8574:57:REGISTER.B5 PP" )
field( OUT, "$(P)$(R)PCF8574:60:REGISTER.B5 PP MS" )
field( ZNAM, "On" )
field( ONAM, "Off" )
}
###################################
# TRANSFORMER ON/OFF #
###################################
#record(bo, "$(P)$(R)TransformerOnOff" ) {
# field( OUT, "$(P)$(R)PCF8574:57:REGISTER.B4 PP" )
# field( ZNAM, "On" )
# field( ONAM, "Off" )
#}
######################################
# TRANSFORMER500 ON/OFF #
######################################
record(bo, "$(P)$(R)Trans500OnOff" ) {
#field( OUT, "$(P)$(R)PCF8574:57:REGISTER.B4 PP" )
field( OUT, "$(P)$(R)PCF8574:60:REGISTER.B3 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
}
######################################
# TRANS TO POWER ON/OFF #
######################################
record(bo, "$(P)$(R)TransToPowerOnOff" ) {
field( OUT, "$(P)$(R)PCF8574:57:REGISTER.B3 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
}
#############################
# ROTARY PUMP2 #
#############################
record( bo, "$(P)$(R)RotatoryPump2" ) {
field( OUT, "$(P)$(R)PCF8574:57:REGISTER.B2 PP" )
field( ZNAM, "On" )
field( ONAM, "Off" )
}
record( bo, "$(P)$(R)RotatoryValve2" ) {
field( OUT, "$(P)$(R)PCF8574:57:REGISTER.B1 PP" )
field( ZNAM, "Open" )
field( ONAM, "Closed" )
}
##############################
# EMERGENCY MODE #
##############################
record( bo, "$(P)$(R)EmergencyModeOnOff" ) {
field( OUT, "$(P)$(R)PCF8574:57:REGISTER.B0 PP" )
field( ZNAM, "On" )
field( ONAM, "Off")
}
#####################################
### 24V commands - Optocoupler Out###
#####################################
record(bo, "$(P)$(R)TMPControllerOn" ) {
field( ZNAM, "Off" )
field( ONAM, "Pulse" )
field( HIGH, "2.5")
field( FLNK, "$(P)$(R)TMPControllerOnInv" )
}
record(calcout, "$(P)$(R)TMPControllerOnInv" ) {
field( INPA, "$(P)$(R)TMPControllerOn NPP MS" )
field( OUT, "$(P)$(R)PCF8574:56:REGISTER.B0 PP MS" )
field( OOPT, "On Change" )
field( CALC, "A?0:1" )
}
record(bo, "$(P)$(R)TMPControllerOff" ) {
field( ZNAM, "Off" )
field( ONAM, "Pulse" )
field( HIGH, "2.5")
field( FLNK, "$(P)$(R)TMPControllerOffInv" )
}
record(calcout, "$(P)$(R)TMPControllerOffInv") {
field( INPA, "$(P)$(R)TMPControllerOff NPP MS" )
field( OUT, "$(P)$(R)PCF8574:56:REGISTER.B1 PP MS")
field( OOPT, "On Change" )
field( CALC, "A?0:1" )
}
record(bo, "$(P)$(R)TMPMotorOn" ) {
field( ZNAM, "Off")
field( ONAM, "Pulse")
field( HIGH, "2.5")
field( FLNK, "$(P)$(R)TMPMotorOnInv")
}
record(calcout, "$(P)$(R)TMPMotorOnInv" ) {
field( INPA, "$(P)$(R)TMPMotorOn NPP MS")
field( OUT, "$(P)$(R)PCF8574:56:REGISTER.B2 PP MS")
field( OOPT, "On Change")
field( CALC, "A?0:1" )
}
record(bo, "$(P)$(R)TMPMotorOff") {
field( ZNAM, "Off")
field( ONAM, "Pulse")
field( HIGH, "2.5")
field( FLNK, "$(P)$(R)TMPMotorOffInv")
}
record(calcout, "$(P)$(R)TMPMotorOffInv") {
field( INPA, "$(P)$(R)TMPMotorOff NPP MS")
field( OUT, "$(P)$(R)PCF8574:56:REGISTER.B3 PP MS")
field( OOPT, "On Change")
field( CALC, "A?0:1")
}
#############################
### TMP1 Controller inputs###
#############################
record(bi , "$(P)$(R)Turbo_PW_Ind" ) {
field( INP, "$(P)$(R)PCF8574:56:REGISTER:READ.B4 NPP NMS")
field( SCAN, "1 second")
field( ZNAM, "ON" )
field( ONAM, "OFF" )
field(FLNK, "$(P)$(R)Turbo_Emergency")
}
record(bi , "$(P)$(R)Turbo_Emergency") {
field( INP, "$(P)$(R)PCF8574:56:REGISTER:READ.B5 NPP NMS")
field( ZNAM, "ON" )
field( ONAM, "OFF" )
field(FLNK, "$(P)$(R)Turbo_Acceleration")
}
record(bi , "$(P)$(R)Turbo_Acceleration") {
field( INP, "$(P)$(R)PCF8574:56:REGISTER:READ.B6 NPP NMS")
field( ZNAM, "ON" )
field( ONAM, "OFF" )
field(FLNK, "$(P)$(R)Turbo_NormalOperation")
}
record(bi , "$(P)$(R)Turbo_NormalOperation" ) {
field( INP, "$(P)$(R)PCF8574:56:REGISTER:READ.B7 NPP NMS")
field( ZNAM, "ON" )
field( ONAM, "OFF" )
}
#####################################
### 24V commands - Optocoupler Out###
#####################################
record(bo, "$(P)$(R)TMP2ControllerOn" ) {
field( ZNAM, "Off" )
field( ONAM, "Pulse" )
field( HIGH, "2.5")
field( FLNK, "$(P)$(R)TMP2ControllerOnInv" )
}
record(calcout, "$(P)$(R)TMP2ControllerOnInv" ) {
field( INPA, "$(P)$(R)TMP2ControllerOn NPP MS" )
field( OUT, "$(P)$(R)PCF8574:61:REGISTER.B0 PP MS" )
field( OOPT, "On Change" )
field( CALC, "A?0:1" )
}
record(bo, "$(P)$(R)TMP2ControllerOff" ) {
field( ZNAM, "Off" )
field( ONAM, "Pulse" )
field( HIGH, "2.5")
field( FLNK, "$(P)$(R)TMP2ControllerOffInv" )
}
record(calcout, "$(P)$(R)TMP2ControllerOffInv") {
field( INPA, "$(P)$(R)TMP2ControllerOff NPP MS" )
field( OUT, "$(P)$(R)PCF8574:61:REGISTER.B1 PP MS")
field( OOPT, "On Change" )
field( CALC, "A?0:1" )
}
record(bo, "$(P)$(R)TMP2MotorOn" ) {
field( ZNAM, "Off")
field( ONAM, "Pulse")
field( HIGH, "2.5")
field( FLNK, "$(P)$(R)TMP2MotorOnInv")
}
record(calcout, "$(P)$(R)TMP2MotorOnInv" ) {
field( INPA, "$(P)$(R)TMP2MotorOn NPP MS")
field( OUT, "$(P)$(R)PCF8574:61:REGISTER.B2 PP MS")
field( OOPT, "On Change")
field( CALC, "A?0:1" )
}
record(bo, "$(P)$(R)TMP2MotorOff") {
field( ZNAM, "Off")
field( ONAM, "Pulse")
field( HIGH, "2.5")
field( FLNK, "$(P)$(R)TMP2MotorOffInv")
}
record(calcout, "$(P)$(R)TMP2MotorOffInv") {
field( INPA, "$(P)$(R)TMP2MotorOff NPP MS")
field( OUT, "$(P)$(R)PCF8574:61:REGISTER.B3 PP MS")
field( OOPT, "On Change")
field( CALC, "A?0:1")
}
#########################################
# TOR-FIELD TRIGGER ON/OFF BO #
#########################################
record(bi, "$(P)$(R)TorFieldTriggerOnOff" ) {
#field( INP, "$(P)$(R)PCF8574:61:REGISTER:READ.B3 NPP NMS" )
field( ZNAM, "On" )
field( ONAM, "Off" )
field( VAL, 1)
}
#############################
### TMP2 Controller inputs###
#############################
record(bi , "$(P)$(R)Turbo2_PW_Ind" ) {
field( INP, "$(P)$(R)PCF8574:61:REGISTER:READ.B4 PP NMS")
field( SCAN, "1 second")
field( ZNAM, "ON" )
field( ONAM, "OFF" )
field(FLNK, "$(P)$(R)Turbo2_Emergency")
}
record(bi , "$(P)$(R)Turbo2_Emergency") {
field( INP, "$(P)$(R)PCF8574:61:REGISTER:READ.B5 NPP NMS")
field( ZNAM, "ON" )
field( ONAM, "OFF" )
field(FLNK, "$(P)$(R)Turbo2_Acceleration")
}
record(bi , "$(P)$(R)Turbo2_Acceleration") {
field( INP, "$(P)$(R)PCF8574:61:REGISTER:READ.B6 NPP NMS")
field( ZNAM, "ON" )
field( ONAM, "OFF" )
field(FLNK, "$(P)$(R)Turbo2_NormalOperation")
}
record(bi , "$(P)$(R)Turbo2_NormalOperation" ) {
field( INP, "$(P)$(R)PCF8574:61:REGISTER:READ.B7 NPP NMS")
field( ZNAM, "ON" )
field( ONAM, "OFF" )
}
#######################
###TMP1 Manual Valve###
#######################
record(bo, "$(P)$(R)TMPManualValve"){
info(autosaveFields, "VAL")
field( DESC, "State of manual valve")
field( ZNAM, "Closed")
field( ONAM, "Open")
}
#########################
###Pressure Conditions###
#########################
record(ao,"$(P)$(R)Pressure_PrimaryCondition"){
field(VAL,"5.0e-3")
field(PREC,"3")
field(EGU,"mBar")
}
record(ao,"$(P)$(R)Pressure_Primary2Condition"){
field(VAL,"5.0e-3")
field(PREC,"3")
field(EGU,"mBar")
}
#record(ai,"$(P)$(R)Pressure_Primary2"){
# field(VAL,"1.0e-3")
# field(PREC,"3")
# field(EGU,"mBar")
#}
record(ai,"$(P)$(R)Bypass_Condition"){
field(VAL,"0")
}
#####################
###Dummy Variables###
#####################
record(ao,"$(P)$(R)Pressure_TMP_admission"){
field(VAL,"1.0e5")
field(PREC,"3")
field(EGU,"mBar")
}

View File

@@ -0,0 +1,18 @@
TOP=../..
include $(TOP)/configure/CONFIG
#----------------------------------------
# ADD MACRO DEFINITIONS BELOW HERE
# Install databases, templates & substitutions like this
DB += ISTTOKstates.db
DB += ISTTOKvacummPumps.db
DB += ISTTOKpcf8574.db
DB += ISTTOKrs485.db
# If <anyname>.db template is not named <anyname>*.template add
# <anyname>_TEMPLATE = <templatename>
include $(TOP)/configure/RULES
#----------------------------------------
# ADD EXTRA GNUMAKE RULES BELOW HERE